COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 2:52:05 PM
Creation date
6/3/2020 9:52:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
532
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br /> O I AMENDEDEnvironmental Health Department <br /> S �? QI Iz I I(A((S Eli]-- COUNTY--.__ <br /> WK- <br /> . F gllbu tar �rt� rar �r1 ecti� BepM-11 f <br /> o <br /> �. t .. <br /> Facility Name: Facility Address: Date: <br /> WESTERN FOOD&FUEL 3032 E WATERLOO RD, STOCKTON December 11, 2018 <br /> SUMMARY OFA IIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 306 CCR 2630(d)Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The site has flexible primary and secondary piping. During the field inspection it was observed that the test boots <br /> appeared completely sealed in the 87 product and 91 product lines in all UDCs.Any potential release from the <br /> primary containment into the secondary containment in the 87 product and 91 product piping does not flow into a <br /> UDC collection sump to detect a leak at the earliest opportunity. Immediately contact a properly licensed,trained, <br /> and certified contractor to ensure that any releases in the 87 product and 91 product piping flows into the nearest <br /> sump for a leak to be detected at the earliest possible opportunity. Ensure that all monitoring equipment is <br /> maintained to detect a leak at the earliest opportunity. <br /> This is a Class I violation. <br /> 307 CCR 2631(g), 2632(c)Monitoring system of the interstitial space of a double walled system not maintained. <br /> The 91 product and diesel product split tank annular sensor failed to come out of audible and visual alarm when <br /> tested and,therefore,the tank is not monitored. The interstitial space shall be monitored with a monitoring system <br /> connected to an audible and visual alarm system. The sensor was replaced and retested during the inspection. A <br /> "UST Retrofit Verification with Inspector Already Onsite"form has been completed and provided to the operator and <br /> contractor. <br /> This is a repeat violation, Class II. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch. <br /> The 87 product VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br /> passed. <br /> This is a repeat violation, Class II. <br /> 320 CCR 2635, 2637.2,2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations,title 23 division <br /> 3, chapter 16 section 2635(c)(2)shall test overfill prevention equipment once by October 13th, 2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair.The site did not performed the testing by October 13th, <br /> 2018 however the service technician on site was able to conduct the overfill prevention equipment inspection today <br /> (12/11/18)while the inspector was on site. Ensure to conduct overfill prevention equipment inspection within the <br /> time frame provided by the regulation and submit test results within 30 days of performing the inspection. Ensure a <br /> 48 hour notification is provided to EHD prior to conducting the inspection. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0002127 PR0231758 SCO01 12/11/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 7 of S Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.