My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 2:52:05 PM
Creation date
6/3/2020 9:52:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
532
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANAOAQUIN Environmental Health Department <br /> Greatness grows here. <br /> M <br /> Facility Name: Facility Phone: Date: <br /> WESTERN FOOD&FUEL (209)346-9232 December 11, 2018 <br /> Facility Address: CERS ID: <br /> 3032 E WATERLOO RD, STOCKTON, CA 95205 10180877 <br /> Inspection Contact Phone: <br /> Varinder Singh operator (209)321-1632 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 12361 -LIST FACILITY <br /> Consent For: Consent Given By: <br /> ED Inspection Z Photos N Samples Dave Khinda, Manager <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> David Winkler 01/31/2020 Alex Jabbari 10/01/2020 <br /> Service Technician Manufacturer's Training: <br /> Veeder Root, 02/08/20;VMI, 11/10/19; Franklin fueling, 11/30/20 <br /> CCR=Title 23 California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> A ta <br /> J <br /> ��,97.NY, <br /> 101 HSC 25284 Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees u V o R o COS <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system Li V o R o COS <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents o V ci R Ei COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current m V c R o COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan o V c R o COS <br /> 12634(d) <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan o V o R o COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed o V o R o COS <br /> 108 CCR 2637,2638(e), Failed to notify the EHD 48 hours prior to conducting testing o V o R o COS <br /> 2643(g) <br /> 109 CCR 2637(a-d),2712 Failed to test secondary containment,or failed to maintain test records for 36 months Ei V o R o COS <br /> 110 CCR 2637(e),2637(f) Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test Ei V o R o COS <br /> Ill CCR 2638(a)&(b), Failed to test monitoring and leak detection equipment annually c V Ei R o COS <br /> 26410) <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance o V o R ii COS <br /> 113 CCR 2638(c),2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the test m V o R o COS <br /> 114 CCR 2636(f)(3),2643(c) No 0.1 gph annual line integrity test for pressurized piping,or within 30 days after repair c V ii R c COS <br /> (3) <br /> 115 CCR 2715(a)(1)(B), "Designated Underground Storage Tank Operator Identification Form"not submitted within 30 days o V o R Ei COS <br /> 2715(a)(3) <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V ii R o COS <br /> 117 CCR 2663, 2712(b)(6) Failure to comply with tank lining,recondkeeping,and inspection requirements ii V o R o COS <br /> 118 CCR 2715(a)(1)(A), Failure to submit the"Underground Storage Tank Statement of Understanding and Compliance Form" ii V o R c COS <br /> 2715(a)(2) <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented o V o R o COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit LIST Certification of Installation/Modification o V c R o COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report m V n R ci COS <br /> 122 CCR 2631,2640.1, Failure to submit and/or maintain documentation regarding Compatibility for UST system components o V o R o COS <br /> 2665,2711 <br /> FA0002127 PR0231758 SC001 12/11/2018 <br /> EHD 23-01 Rev.09128/2018 Page I of 4 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 IF 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.