My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 2:52:05 PM
Creation date
6/3/2020 9:52:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
532
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br /> SAJOAQUIN <br /> - COUNTY -- <br /> .,rFILE COPY <br /> ra <br /> r .Facility Name: Facility Phone: Date: <br /> WESTERN FOOD&FUEL (209)346-9232 September 27, 2018 <br /> Facility Address: CERS ID: <br /> 3032 E WATERLOO RD,STOCKTON, CA 95205 10180877 <br /> Inspection Contact: Title: Phone: <br /> Varinder Singh Business owner (209) 346-9232 <br /> Inspection Type: Program: <br /> INSPECTION/REINSPECTION (Chargeable) 12361 - LIST FACILITY <br /> Consent For: Consent Given By: <br /> M Inspection N Photos N Samples Varinder Singh, Business owner <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Felix Ramirez 11/22/2018 Alex Jibbari 10/03/2018 <br /> Service Technician Manufacturer's Training: <br /> Veeder Root, 07/08/20;VMI, 11/17/19;Tank Tester, 05/31/20 <br /> CCR=Title 23 California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> Fate Review ' <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees o V o R o COS <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system o V o R c COS <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted ❑V o R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current o V o R o COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan Ei V o R o COS <br /> 12634(d) <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan E V ii R Ei COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed o V o R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V o R Ei COS <br /> 109 CCR 2637 Failed to test secondary containment ii V o R c COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days Ej V o R ci COS <br /> ill CCR 2638(a) Failed to test monitoring and leak detection equipment annually o V o R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually Ei V o R ii COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ci V ii R E COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ci V o R o COS <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change w/in 30 days Ei V o R Ei COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V o R Ei COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V o R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests o V o R o COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented o V o R o COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification n V o R o COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report Ei V ii R Ei COS <br /> 122 CCR 26310) Failure to submit and maintain UST system component statement of compatibility for substance stored E)V o R o COS <br /> A <br /> `6'd <br /> % <br /> ed <br /> s <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records o V Ei R o COS <br /> FA0002127 PR0231758 SC333 09/27/2018 <br /> EHD 23-01 Rev.10/31/2017 Page I of 4 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.