My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
5611
>
2300 - Underground Storage Tank Program
>
PR0231764
>
COMPLIANCE INFO_1996-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 4:13:37 AM
Creation date
6/3/2020 9:52:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2002
RECORD_ID
PR0231764
PE
2361
FACILITY_ID
FA0002160
FACILITY_NAME
BlackHawk Petroleum Inc.
STREET_NUMBER
5611
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710052
CURRENT_STATUS
01
SITE_LOCATION
5611 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231764_5611 E WATERLOO_1996-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14. ORLANDO ' S BAIT AND TACKLE 5611 WATERLOO ROAD STOCKTON CALIF. 11/05/92 <br /> Name of Supplier.Owner at Dealer Address No.and Street(a) City State Date of Test <br /> 15. TANK TO TEST 15a. BRIEF DIAGRAM OF TANK FIELD 16.CAPACITY From <br /> ❑ Station Chan <br /> EAST WEST Nominal Capacity 8,000 ❑ Tank Manufacturers chart <br /> Identify by position Gallons ® Company Engineering Data <br /> PREMIUM By mat aocurata8,000 <br /> /� ❑ Chane supplied with Tank Tatter <br /> stand and Grade ca rt Chan 8 available ,0 0 0 ❑ Other <br /> Gallons <br /> 17. FILL-UP FOR TEST Total Gallons <br /> ea.Reading <br /> Stich water Bottom <br /> f <br /> el0 0 95 Inventory in rank .8 0 0 0 <br /> be Fill-upIn. In. <br /> to K' Gallons Tock Diameter <br /> Water Bottom — 0 <br /> 1.8. SPECIAL CONDITIONS AND PROCEDURES TO TEST THIS TANK ❑Water In tank ❑ Uns(s)being tested with LVLLT Top off equipment 10 <br /> See manual sections appttcable.Check below and record procedure In log(27). ❑High water table In tank excavation Total Ouantity 8,010 <br /> Los maximum allowable test pressure for as tats. 19. TANK MEASUREMENTS FOR <br /> Four pound.rule does not aptly to douotewaged tanks. TSTT ASSEMBLY . <br /> Complete section below: <br /> 21. VAPOR RECOVERY SYSTEM ❑stag.t ❑slay.�1 <br /> Bottom of tank to grade*............................ 160 In. <br /> Add 30"for"T"probe easy........................... 30 In. 24b.COEFFICIENT OF EXPANSION <br /> 1. is four pound rule required? Yes ❑ No ❑ Total tubing to assemble—approximate............. In. RECIPROCAL METHOD <br /> 14 20. EXTENSION HOSE SETTING Type of Product................... <br /> PREMIUM <br /> 2.'He"b t7 Mark koro pada M. <br /> Tank top to grade*.................................. 65 in. HydrometerEmployed.................................. <br /> 4. 55 2 Extend hose on suction tube S"o more Temperature In Tank 68. <br /> 3.Pressure al bottom of tank P.S.I. After Circulation........................................ F <br /> belowtank top...................................... in. <br /> 4. Pressure at top of lank --- l� <br /> 2,5 4 P.S.I.P.S.i. •11 Fill pipe extends above grade.use top of fill. Temperature of Sample................................. _!st•F <br /> OUSE WITH THERMAL SENSOR Difference(*/-)......................................... +2•F <br /> Depth of burial In. PN5039(Blue Box) Observed A.P.I.Gravity ................................. 59 .4 <br /> 22. Thermal-Sensor reading after circulation di1473 63 <br /> g4s Reciprocal a <br /> Tarok die. 95 In. •F <br /> BELOW Between 8,010 , 1473 5.4378818 <br /> 10 <br /> 23. Digits per•F in range of expected change Total quantity in Reciprocal Volume change in <br /> Water table to tank bottom TANK indigits full tank(17) this tank per IF <br /> Transfer to Line 26. <br /> NOTES: <br /> DOMES IC WELL M24a. IF USING THERMAL SENSOR DTS-2000 <br /> OR OC-2000 WHICH READ 1000 DIGITS 24c. FOR TESTING WITH WATER "sT.bsCaD <br /> PER OF TRANSFER 1000 TO LINE 26, <br /> Water Temperature after DIGITS PER OF IN TEST RANGE. Table Ctom Thermal Seniwr Circulation...................... •F <br /> 68 .633 <br /> Coefficient of water <br /> The above calculations are to be used for dry soil conditions to Tabs D................................................ <br /> establish a positive pressure advantage.or when using the four pound <br /> rule to compensate for the presence of subsurface water In the tank Added Surfactant? ❑Yea ❑No Transfer COE to Line 2%. <br />_ area <br /> Refer to N.F.P.A. 30. Sections 2.3.2.4 and 2-7.2 and the tank Y5. (a) x (b) c W gallons <br /> manufacturer regarding allowable system tat pressures. Total quantity in Coefficient of expansion for Volume change in this tank <br /> full tank(17) Involved product per•F <br /> 26. (a) 5.4378818 1 ,000 .0054378 This 14 <br /> Volume change per•F(25 or 24b) Digits per•F in test Volume change per digitlest 5 4 <br /> Range(23 or 24s) Compute to 4 decimal places. fact"(a) . <br />
The URL can be used to link to this page
Your browser does not support the video tag.