Laserfiche WebLink
Nam4 of Supplier.Owner or Dealer <br /> Address NO.and Street(s) Dale of <br /> City State Test <br /> From <br /> 15. TANK TO TEST 15a. BRIEF DIAGRAM OF TANK FIELD 16. CAPACITY <br /> ❑ Station Chart <br /> ❑Nominal Capacity '�'� Tank Manufacturer's Chart <br /> I c/ <br /> Gallons <br /> ❑ Company Engineering Data <br /> /+dentity by position <br /> / ❑ Charts supplied with <br /> S By most accurate ' ") <br /> Brand and Grade capacity chart available {� � ❑ Other <br /> Gallons <br /> Total Gallons <br /> 17. FILL-UP FOR TEST /? Gallons ea.Reading <br /> Stick Water Bottom j J ) <br /> before Fill-up in. <br /> in. Inventory <br /> / 0�� <br /> to h'• Gallons Tank Diameter _ "....�._. —. <br /> 1 <br /> 18, SPECIAL CONDITIONS AND PROCEDURES TO TEST THIS TANK ❑Water In tank ❑ Line(s)being tested with LVLLT <br /> See manual sections applicable.Check below and record procedure in log(27). ❑High water table in tank excavation <br /> Transfer total to line 25a <br /> Use maximum allowable test pressure for all tests. 19. TANK MEASUREMENTS FOR <br /> Four pound rule does not apply to doublewalled tanks. TSTT ASSEMBLY 21. VAPOR RECOVERY SYSTEM ❑ ❑ <br /> Stage 1 Stage II <br /> Complete section below: Bottom of tank to grade' .....................I...... in. <br /> Add 30"for IT'probe&say........................... 30 In. 241). COEFFICIENT OF EXPANSION <br /> .t. Is four pound rule required? Yes ❑ No ❑ Total tubing to assemble—approximate............. in. RECIPROCAL METHOD <br /> J Na <br /> Type o1 Product ........................................L. ._ <br /> 20. EXTENSION HOSE SETTING /? <br /> 2.Height to 12"mark from bottom of tank in. Tank top to grade'.................................. H <br /> in. Hydrometer Employed ................................... <br /> /�•1� hhryL1 Extend hose on suction tube 6"or more Temperature In Tank F���J <br /> �C1.✓�P.S.I. Atter Circulation........................................ °F <br /> 3. Pressure at bottom of tank ,,,,,,,,,,,, in. <br /> below lank top•••••••••••••••••••••••••• �� • <br /> Q Temperature of Sample................................. `" °F <br /> r ✓ .. P.S.I. 'if Fill pipe extends above grade,use top of fill. _ r <br /> 4. Pressure at top of tank G OF <br /> 22. Thermal-Sensor reading after circulation Difference(°/-)......................................... <br /> digits <br /> �:f r <br /> 1" � °F Observed •••••• <br /> in. y ....................;./...% <br /> Depth of burial _ �� •h <br /> ,l 23. Digits per OF in range of expected change Reciprocal (6 > Page If <br /> `i digits 9 <br /> Tank dia. ✓ in. - •� ��. pi ���•. <br /> r1 r j• <br /> COEFFICIENT OF EXPANSION (Complete after circulation) — <br /> 24a. corrected A.P.I.Gravity Total quantity in Reciprocal a Volume change in <br /> lull tank(16 or 17) this tank per OF <br /> Water table in. Observed <br /> to Line 26a. <br /> Observed A.P.I.Gravity................................... <br /> NOTES: <br /> . Hydrometer employed................................... H <br /> 24c. FOR TESTING WITH WATER see Table C&D <br /> Observed Sample Temperature ......................... °F <br /> Corrected A.P.I.Gravity Water Temperature after Circulation <br /> @6WF,From Table A.................................... Table C................................................ <br /> °F <br /> Coefficient of Expansion Coefficient of Water <br /> The above calculations are to be used for dry soil conditions to <br /> for Involved Product Table D................................................ <br /> FromTable 8............................................ <br /> establish a positive pressure advantage.orwhen using the four pound Added Surfactant? ❑Yes ❑No Transfer COE to Line 25b. <br /> rule to compensate for the presence of subsurface water In the tank Transfer COE to Line 25b. <br /> area. (1)) _ (�) <br /> Refer to N.F.P.A. 30, Sections 2-3.2.4 and 2-7.2 and the tank 25, (a) x gallons <br /> manufacturer regarding allowable system test pressures. Total quantity In Coefficient of expansion for Volume change In this tank <br /> lull tank(16 or 17) Involved product per OF <br /> 26, (a) <�,./d'I( � 3 CHCS = , i �7 This Is <br /> Vnlumr,change per OF(25 or 24b) Digits per OF In test Volume change per digit test .,. <br />