Laserfiche WebLink
SAN JOAQUIN41T <br /> Y PUBLIC HEALTH SERVICES/ENVIRONMENTAL HEff DIVISION <br /> I. WORKSHEET FOR SITE CLOSURE EVALUATION DATE <br /> NAME OF FACILITY ' '� SWEEPS CODEI <br /> ADDRESS � // 5, �oG TANK ID # <br /> TANK SIZE FUEL TYPE Q c, <br /> 1I. GENERAL SITE HISTORY <br /> Is permit current? Yes No Permit # - Facility Status Code Doc.SoiI/GW Cant Yes No <br /> Number of Tanks at facility Age of Tanks(if available) Type of Tank Steel Fbrgt Sngl Dual <br /> 1I1. TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test ? Yes No If yes, give date(s) <br /> Was a repair made to the tank system? Yes No IIf yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed? YesNo BTXE TPH-G TPN-0 Pb/EDB <br /> Type of failure/discharge catastrophic long-term leakage) overfill unknown other: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes No Depth to Ground Water Ref/Year Average Annual Precipitation A= 14 10-25 <br /> On-Site Wells) Yes No Number & Type Irr Dom Pub <br /> S Score S Score S Score <br /> Distance to Wells) from Tank ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potential Analysis E is met E is met E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) >100 I 1 51-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) None Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10-25 Ixxxxxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration I <br /> of leachate (i.e., septic systems, water wells, ponds) None Unknown - Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. Cl At least More than <br /> xxxxxx None one one <br /> COLUMN TOTALS»>TOTAL POINTS <br /> Sample Result: (B T X OR E) RANGE OF TOTAL POINTS 49 pts or more 41 - 48 pts 40 pts or less <br /> 1 1., B T X E B T X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. 1. NA\3 <br /> Sample Result: _ GASOLINE 1000 100 10 <br /> MAXIMUM ALLOWABLE TPH LEVELS (PPM) <br /> �i(e h)=37d TPH C- DIESEL 10,000 1000 100 <br /> FOOTNOTES* ***If documented soil and/or ground water contamination is present, do no i the leaching potential <br /> 50_P14 C., analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth -5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION �O Ie, f�+ � �I <br /> 1. Are BTX & E or TPH Concentrations > Allowable Levels *Yes No ,,,, <br /> 2. Recommend Site Closure Yes No If Yes, Refer to Site Mitigation for Evaluation (q't��U� <br /> VII. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES NO REFERRED TO SITE MITIGATION FOR EVALUATION YES NO <br /> DATE REFERRED / / DATE CLOSURE LETTER MAILED <br /> NAME OF <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 <br />