My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
5611
>
2300 - Underground Storage Tank Program
>
PR0231764
>
COMPLIANCE INFO_1996-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 4:13:37 AM
Creation date
6/3/2020 9:52:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2002
RECORD_ID
PR0231764
PE
2361
FACILITY_ID
FA0002160
FACILITY_NAME
BlackHawk Petroleum Inc.
STREET_NUMBER
5611
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710052
CURRENT_STATUS
01
SITE_LOCATION
5611 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231764_5611 E WATERLOO_1996-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Amk <br /> IJWIFIED PROGRAM CONSOLIDATED FOR ' <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> Page of <br /> VI.PIPING'CONSTRUC71ON(Check a8 that appy) <br /> UNDERGROUND PIPING ABOVEGROYND PIPING <br /> SYSTEM TYPE ❑ 1 PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY ❑ 1. PRESSURE ❑ 2. TION ❑ 3. GRAVITY <br /> CONSTRUCTION/ ❑ 1. SINGLE WALL ❑ 3. LINED TRENCH ❑99. OTHER ❑ 1. SINGLE WALL ❑95. UNKNOWN <br /> MANUFACTURER ❑ 2. DOUBLE WALL ❑95. UNKNOWN ❑ 2. DOUBLE WALL ❑99. OTHER <br /> MANUFACTURER MANUFACTURER <br /> ❑ 1.BARE STEEL ❑ 8. FRP COMPATIBLE WI 100%METHANOL ❑ 1. BARE STEEL ❑ 6. fRP COMPATIBLE WI 100%METHANOL <br /> MATERIALS AND ❑ 2, STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑95. UNKNOWN ❑ 3. PLASTIC COMP BLE WITH CONTENTS ❑ 8. FLEXIBLE(HDPE) ❑99. OTHER <br /> ❑ 4. FIBERGLASS ❑ 8. FLEXIBLE(HDPE) ❑99. OTHER ❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br /> ❑ S. STEEL W/COATING ❑ 9.CATHODIC PROTECTION ❑ 5. STEEL W/ DATING ❑95. UNKNOWN <br /> VII.PIPING LEAK DETECTION(Chet a8 that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING - <br /> PRESSURIZED PIPING(Check alf that appy): PRES RIZED RTEST <br /> eck all that apply): - <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPM TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRLEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUTOFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEMAND SYSTEM DISCONNECTION;AUDIBLE AND VISUAL ALARMS <br /> ALARMS 2. MONTH <br /> ❑ 2. MONTHLY 0.2 GPH TEST <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) 114. DAILY VISUAL CHECK - <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that appy): - <br /> ❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SELF MONITORING1a4PV&W <br /> ❑ 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ 8. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISU L ALARMS AND RMS AND(check one)10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALA <br /> (Check one) _ <br /> ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILUR AND SYSTEM ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> ❑ 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST))WIT FLOW SHUT OFF OR ❑ 11, AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND V UAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS O LY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT A PUMP SHUT OFF+AUDIBLE AND ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 H TEST)WITHOUT FLOW SHUT OFF OR ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILY VISUAL CHECK ❑ 1T DAILY VISUAL CHECK <br /> VHI:'DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1. F OAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATE INSTALLED ❑ 2. ONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS 11 5.TRENCH LINER/MONITORING <br /> ❑ . CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ S. NONE <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that the information prov'ed herein is true and accurate to the best of my knowledge. <br /> SIGNATURE OF OWNER/CPfRATOR DATE <br /> NAME OF OWNERIOPERATOR(print) TITLE OF OWNERiOPERATOR <br /> Permit Number(For local use only) Permit Approved(For local use ony) Permit Expiration Date(For local use only) <br /> CUPAFORM(4/99) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.