Laserfiche WebLink
SY M SET-UP REPORT age 2) <br /> T 3:PLUS - <br /> PRODUCT CODE 3 T 4:1)IESEL. LEAK TEST METHOD <br /> THERMAL COEFF : .000700 PRODUCT CODE 4 <br /> TANK. DIAMETER 96.00 THERMAL COEFF : .000450 TEST ON DATE : ALL TANK <br /> TANK. PROFILE 1 PT TANK DIAMETER 96.00 NOV 10, 2003 <br /> FULL VOL 10000 TANK PROFILE 1 FIT START TIME : DISABLED <br /> FULL VOL 12000 TEST RATE :0.20 GAL,'HR <br /> DURATION : 2 HOURS <br /> FLOAT SIZE: 4.0 IN. FLOAT SIZE: 4.0 IN. TST EARLY STOP:DISABLED <br /> WATER i,,IARNING 1 .0 <br /> HIGH WATER LIMIT: 2.0 WATER WARNING 1 .0 LEAK TEST REPORT FORMAT <br /> HIGH WATER LIMIT: 2.0 r,I rlL,M"I <br /> MAX OR LABEL VOL: 10000 LIQUID SENSOR SETUP <br /> OVERFILL LIMIT 90% MAX OR LABEL VOL: 12000 <br /> 9000 OVERFILL LIMIT 90 <br /> HIGH PRODUCT 95% 10800 L 1 :PLUS ANNULAR <br /> 9500 HIGH PRODUCT 95% TRI-==TATE (SINGLE FLOAT) <br /> DELIVERY LIMIT 104 11400 CATEGORY : ANNULAR SPACE <br /> 1000 DELIVERY LIMIT 100, <br /> 1200 <br /> LOW PRODUCT : 1000 LOW PRODUCT' 1000 c <br /> LEAK ALARM LIMIT: 99 L 2:ELUS STP SUMP <br /> SUDDEN LOSS LIMIT: 99 LEAK ALARM LIMIT: 99 TRI-STATE (SINGLE FLOAT) <br /> TANK TILT 0.00 SUDDEN LOSS LIMIT: 99 CATEGORY : STP SUMP <br /> PROBE OFFSET 0.00 TANK TILT 0.00 <br /> PROBE OFFSET 0.00 <br /> L 3:UNLEADED ANNULAR <br /> SIPHON MANIFOLDED TANKS SIPHON MANIFOLDED TANKS TRI -STATE iSINGLE FLOAT) <br /> Tit: NONE CATEGORY : ANNULAR SPACE <br /> LINE (°IANIFOLDED TANKS TO: NONE <br /> TO: NONE LINE MANIFOLDED TANKS <br /> TO: NONE <br /> L 4:UNLEADED STP SumP <br /> LEAK MIN PERIODIC: 0% TRI-STATE (SINGLE FLOAT) <br /> 0 LEAK MIN PERIODIC: 0% CATEGORY : STP SUMP <br /> LEAK MIN ANNUAL 0% <br /> 0 LEAK MIN ANNUAL 0% L 5:Li1ESEL ANNULAR <br /> 0 TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : ANNULAR SPACE <br /> PERIODI[: TEST TYPE <br /> STANDARD PERIODIC PEST TYPE <br /> STANDARD <br /> ANNUAL TEST FAIL L 6:LiIESEL STP SUMP <br /> ALARM DISABLED ANNUAL TEST FAIL TRI-STATE (SINGLE FLOAT) <br /> ALARM DISABLED CATEGORY STP SUMP <br /> PERIODIC TEST FAIL <br /> ALARM DISABLED PERIODIC TEST FAIL <br /> ALARM DISABLED <br /> GROSS TEST FAIL <br /> ALARM DISABLED CROSS TEST FAIL <br /> ALARM DISABLED <br /> ANN TEST AVERAGING: OFF <br /> PER TEST AVERAGING: OFF ANN TEST AVERAGING: OFF <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF <br /> TANK TEST NOTIFY: OFF <br /> TNK TST SIPHON BREAK:OFF <br /> TNK TST SIPHON BREAK.:OFF <br /> DELIVERY DELAY 5 MIN <br /> PUMP THRESHOLD : 10.00% DELIVERY DELAY 5 MIN <br /> PUMP THRESHOLD 10.00% <br /> ©2006 Walton Engineering,Inc. <br />