Laserfiche WebLink
0 • <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared <br />for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br />days of test date. <br />A. General Information <br />Facility Name: Nella Oil #427 <br />Site Address: 3300 Waterloo RD. <br />Facility Contact Person: Kristin Ford <br />Make/Model of Monitoring System: Gilbarco EMC <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />City: Stockton <br />Contact Phone No.: <br />Bldg. No.: <br />Zip: 95205 <br />Date of Testing/Servicing: 12 /06 /2005 <br />Tank ID: Gasoline - 87 <br />Tank ID: Gasoline -89 <br />M In -Tank Gauging Probe. <br />Model: 0847390-109 <br />■ In -Tank Gauging Probe. <br />Model: 0847390-109 <br />0 Annular Space or Vault Sensor. <br />Model: 0794390-420 <br />■ Annular Space or Vault Sensor. <br />Model: 0794390-420 <br />■ Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />■ Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />■ Mechanical Line Leak Detector. <br />Model: FE -Petro MLD <br />■ Mechanical Line Leak Detector. <br />Model: Red Jacket FX <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other(specify equipment a and model in Section E on Pae 2). <br />❑ Other (specify equipment a and model in Section E on P e 2). <br />Tank ID: Diesel <br />Tank ID: <br />0 In -Tank Gauging Probe. <br />Model: 0847390-109 <br />❑ In -Tank Gauging Probe. <br />Model: <br />E Annular Space or Vault Sensor. <br />Model: 0794390-420 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />E Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />■ Mechanical Line Leak Detector. <br />Model: Red Jacket FX <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify a ui ment a and model in Section E on Page 2). <br />❑ Other (speciLy a ui ment type and model in Section E on P2je 2). <br />Dispenser ID: 1 <br />Dispenser ID: 2 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Shear Valve(s). <br />■ Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />E Dis nser Containment Float(s) and Chain(s). <br />Dispenser ID: 3-4 <br />Dispenser ID: 5-6 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />E Shear Valve(s). <br />M Shear Valve(s). <br />E Dispenser Containment Float(s) and Chain(s). <br />0 Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 7 <br />Dispenser ID: 8 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />N Shear Valve(s). <br />■ Shear Valve(s). <br />EDis enser Containment Float(s) and Chain(s). <br />■ Dispenser Containment Floats and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): Q System set-up x❑ Alarm histo eport <br />Technician Name (print): Mike Lawrence Signature'--L�4�>� <br />Certification No.: 006-05-2104 <br />License. No.: 617238 <br />Testing Company Name: Walton Engineering, Inc. Phone NoA 916 ) 373-1152 <br />Site Address: 3900 Commerce Drive, West Sacramento, CA 95691 <br />UN -036 - 1/4 <br />COPA: San Joaquin Co. Env. Health <br />INSPECTOR: Michelle Le <br />Page 1 of 4 <br />WALTON — = <br />i'4 -� s E` *A l ex 1 N Cr <br />www.unidocs.org <br />Date of Testing/Servicing: 12 /06 /2005 <br />Rev. 06/04/01 <br />