Laserfiche WebLink
UNDER DISPE&ER CONTAINMENT(AC) ( AC TESTING <br />Test Method By: o Manufacturer <br />Test Method Uses: O Pressure <br />Measuring Equipment Used: INCON <br />• Industry Standard o Professional Engr c Other (see below) <br />o Vacuum • Hydrostatic o Other (see below) <br />TS -STS (Electronic Sump Test System) <br />Description <br />Disp # 7 <br />Disp # 8 <br />Disp # 9/10 <br />Disp # 11/12 <br />0:13 <br />UDC manufacturer <br />UDC material <br />UDC depth (inches) <br />Bravo <br />Steel <br />9 <br />Bravo <br />Steel <br />9 <br />Bravo <br />Steel <br />9 <br />Bravo <br />Steel <br />9 <br />11:55 AM <br />Initial Probe Reading <br />Height from UDC bottom to highest <br />piping penetration <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />12:10 PM <br />12:10 PM <br />Height from UDC bottom to lowest <br />electrical penetration <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />0.7903 <br />1.0116 <br />Condition of UDC prior to testing <br />Port <br />Dry <br />Dry <br />Dry <br />Dry <br />Change in water level (t 0.0000 inches) <br />-0.0016 <br />0.0008 <br />0.0003 <br />0.0006 <br />ion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Float <br />Float <br />Was sensor removed for testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />6 <br />6 <br />6 <br />6 <br />Wait time for water level to stabilize (hr:min) <br />0:07 <br />0:10 <br />0:13 <br />0:15 <br />Test start time <br />11:55 AM <br />11:55 AM <br />11:55 AM <br />11:55 AM <br />Initial Probe Reading <br />0.2855 <br />1.3438 <br />0.7900 <br />1.0110 <br />Test end time <br />12:10 PM <br />12:10 PM <br />12:10 PM <br />12:10 PM <br />Final Probe Reading <br />0..2839 <br />1.3446 <br />0.7903 <br />1.0116 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0016 <br />0.0008 <br />0.0003 <br />0.0006 <br />ion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Float <br />Float <br />Was sensor removed for testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />6 <br />6 <br />6 <br />6 <br />Wait time for water level to stabilize (hr:min) <br />0:07 <br />0:10 <br />0:13 <br />0:15 <br />Test start time <br />11:55 AM <br />11:55 AM <br />11:55 AM <br />11:55 AM <br />Initial Probe Reading <br />0.2855 <br />1.3438 <br />0.7900 <br />1.0110 <br />Test end time <br />12:10 PM <br />12:10 PM <br />12:10 PM <br />12:10 PM <br />Final Probe Reading <br />0..2839 <br />1.3446 <br />0.7903 <br />1.0116 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0016 <br />0.0008 <br />0.0003 <br />0.0006 <br />Pass/Fail threshold (10.0020 inches /; Hr.) <br />TEST RESULT <br />0.0020 <br />PASS <br />0.0020 <br />PASS <br />_ <br />0.0020 <br />PASS <br />0.0020 <br />PASS <br />© 2004 Walton Engineering, Inc. <br />