My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_1995-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:16:06 PM
Creation date
6/3/2020 9:52:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2006
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_1995-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Dec 10 03 09:43a p.2 <br />D. Results of Testing/Servicing <br />"oftwa) e Version Installed: ) ;z LD / <br />Comph to the following checklist: <br />1, r"�;es_ ❑ No* Is the audible alarm operational? <br />fi )-Yes O No* Is the visual alarm operational? <br />G r-Y� ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br />C I" Yes 13No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />C sO No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />�.-- ❑ NIA operational? <br />"Xes I ❑No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />C3 N/A monitoring system detects a leak, fails to operate, ��or.,.�* electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) W-Su-mptTrench Sensors; ❑ Dispenser Containment Sensors. <br />Did yon confirm positive shut -down due to leaks and sensor failure/disconnection? U-7'e's; ❑ No. <br />® Yes I ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (Le. no <br />❑"NTA mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />_ fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % <br />❑ Yes* o Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />_ and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes* cmb Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product, ❑ Water. If yes, describe causes. in Section E, below. <br />f� Ves 0 No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />Ca' >tes O No* Is all monitoring equipment operational per manufacturer's specifications? <br />* Ir Sectic n E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />ti <br />Page 2 of 3 <br />03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.