My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_1995-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:16:06 PM
Creation date
6/3/2020 9:52:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2006
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_1995-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIED PROGRAM CONSOLIDATED FO <br /> TANKS <br /> UNDERGROUND STORAGET - TANK PAGE 1 <br /> (two pages per tank) <br /> Page_of_ <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ® 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: 1 <br /> 3 , <br /> NELLA Oil Company 427 <br /> LOCATION WITHIN SITE,Optional) 431 <br /> Underground Storage Tanks south of building <br /> 1.TANKDESCRIPTION (A scaled plot planc with the location of the UST system including buildings an&landmarks shall be submitted to the;local <br /> agency.). <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes Z No 434 <br /> 42702 unknown If"Yes".complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> unknown 10000 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® 1. MOTOR VEHICLE FUEL ❑ 1a. REGULAR UNLEADED ❑2 LEADED ❑5 JET FUEL <br /> (If marked complete Petroleum Type) Z lb. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> [:12. NON-FUEL PETROLEUM ❑1c. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑4. HAZARDOUS WASTE Premium Unleaded Gasoline 92 Octane 86290-81-5 <br /> (Includes Used Oil) <br /> [:195 UNKNOWN <br /> 11L. TANK CONSTRUCTION <br /> TYPE OF TANK Ell. SINGLE WALL [:13.SINGLE WALL WITH ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only; EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> Z 2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑ 1 BARE STEEL ❑3. FIBERGLASS,,PLASTIC ❑5. CONCRETE ❑95. UNKNOWN 444 <br /> I <br /> ;Check one iter,cci% ❑2 STAINLESS STEEL Z 4 STEEL CLAD W/FIBERGLASS [18. FRP COMPATIBLE W/ ❑99 OTHER <br /> REINFORCED PLASTIC(FRP) 100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1 BARE STEEL ❑3. FIBERGLASS/PLASTIC Q 5. CONCRETE ❑95 UNKNOWN 445 <br /> (Check one item only) Q 2, STAINLESS STEEL Z 4 STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99 OTHER <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> ❑5. CONCRETE [110.COATED STEEL <br /> TANK INTERIOR LINING ❑ 1 RUBBER LINED ❑3.EPDXY LINING [15.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING Z 6 UNLINED Q 99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC Z 3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 446 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all 2 1 SPILL CONTAINMENT <br /> that apply) Yes El1 ALARM ®3 FILL TUBE SHUT OFF VALVE <br /> ®2 DROP TUBE yes ❑2 BALL FLOAT ❑4 EXEMPT <br /> ®3 STRIKER PLATE Yes <br /> ' hu.TANK <br /> LEAK,DIETECTtON(A descnption of the monitoring program shall be submitted to the)J al.agency) <br /> f o_ <br /> IF SINGLE WALL TANK(Checkall that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> Q 1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE IZ 2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG [:17 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> +(SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> V.TANK CLOSURE INFORMATION?PERMANENT CLOSURE IN PLACE <br /> 455 ES N,i9-ED QUANTITY OF SUBSTANCE co 457 <br /> ESTiNia cT�S�L 'YR ,O:GAYJ <br /> REMAINING TANK FILLED WITH INERT MATERIAL? <br /> � <br /> gallons ❑ Yes ❑ No <br />
The URL can be used to link to this page
Your browser does not support the video tag.