Laserfiche WebLink
SAN JOAQUIN COUNTY DATE I I <br />VIRONMENTAL HEALTH DEPARTT PR# <br />PAGE <br />304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br />(209) 468-3420 <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility Name t. Z rFacility Address ifDAID <br />Facilty Contac Title X Phone # l/ <br />UST# Product UST#-& Product UST# Product ST# Pro duct Overfill Prevention: ❑ AudibleNiw al Mechanical Monitoring Panel: ,G <br />Piping System: ElN Gravity Pressure ❑ Suction Violations: V inor ❑ Major <br />Automatic Pump Shut Down Satisfies CCR 2636 (g): ❑ Yes KNo Dispenser Pan: 9Yes ❑ No <br />s <br />UNITIIVUST/INSP (rev 724/02) <br />INSPECTION TYPE: <br />NRoutine Wonitoring Certification <br />❑Complaint <br />❑Install ❑Removal <br />❑Repair/Upgrade <br />COMPANY NAMEAEEOF42A <br />TECHNICIAN NAME: <br />PHONE: — [/Z <br />VIOLATION(S) <br />The above facility is not in compliance with the following <br />section(s) <br />of Health & Safety Code (HSC) and/or <br />California Code of Regulations (CCR): <br />1 <br />HSC 25284 <br />Permit to operate <br />20 <br />CCR 2712 (b) <br />Maintenance & monitoring <br />2 <br />CCR 2637 <br />Secondary cont testing (6 <br />records <br />month/36 month) <br />2 <br />1C 2636 (f)(4) <br />Annual line tightness test <br />3 <br />CCR 2711(b) & (c) Current State Forms A & B <br />22 <br />CCR 2630 (d) <br />Annual line leak detector test <br />4�HSC 25292.2 <br />Certification of financial <br />23 <br />CCR 2630 (d) <br />Annual monitoring certification <br />responsibility and letter from <br />24 <br />CCR 2643 (d) <br />Daily monitoring of suction <br />chief financial officer <br />piping that is not continuously <br />5 <br />CCR 2630 (d) <br />Continuous monitoring system <br />monitored <br />for UST system <br />25 <br />CCR 2636 (a) <br />Conventional suction piping <br />6 <br />CCR 2636 (c)(1) <br />All releases in secondary piping <br />shall have continuous <br />flow to a collection sump <br />monitoring & 20 containment <br />7HSC <br />25291 (e) <br />Water in secondary (20) cont <br />26 <br />CCR 2643 (e) <br />Biennial tightness test of gravity <br />8 <br />HSC 25291 (f) <br />Automatic line leak detector(s) <br />piping that is not continuously <br />9 <br />CCR 2636 (f)(1) <br />Continuous monitoring system <br />monitored <br />for underground piping <br />27 <br />CCR 2662 <br />Upgrade requirements for UST <br />10 <br />CCR 2632 (c)(2) <br />Continuous monitoring system <br />system <br />for UST <br />28 <br />CCR 2661 <br />Permit to repair UST system <br />11 <br />HSC 25291(a)(2) <br />Secondary containment for <br />29 <br />HSC 25286 (a) <br />Permit to alter monitoring <br />UST is tight <br />system <br />12___�/_CCR <br />2636 (f)(1) <br />Continuous monitoring system <br />30 <br />HSC 25298 (a) <br />Illegal abandonment of UST <br />y/ <br />for dispenser system <br />system <br />13 <br />CCR 2635 (b)(1) <br />Spill container <br />31 <br />HSC 25298 (b) <br />Permit to temporarily close UST <br />14 <br />CCR 2635 (b)(2) <br />Overfill prevention system <br />system <br />15 <br />CCR 2631 (a) <br />Primary containment is product- <br />32 <br />HSC 25298 (c) <br />Permit to close UST system <br />16 <br />HSC 25292.1 <br />tight <br />UST system is operated to <br />33 <br />HSC 25291 (e) <br />Water in 20 cont analyzed and <br />properly disposed of <br />prevent unauthorized release <br />34 <br />CCR 2640 (e) <br />Single wall component within <br />17 <br />CCR 2650 <br />Recording/reporting <br />1000' of Public Well, no ELD <br />unauthorized release <br />35 <br />CCR 2635(a)(2)(A) <br />Cathodic protection testing <br />18 <br />CCR 2632 (d) <br />Monitoring & response plan <br />36 <br />H&SC 25299(a)(9) <br />Disabling leak detect. devices <br />19 <br />CCR 2712 (i) <br />Monitoring & response plan is <br />37 <br />Violation(s) not listed above <br />on site <br />EHD INSPEC <br />PHONE: <br />RECEIVED BY: <br />TITLE: <br />UNITIIVUST/INSP (rev 724/02) <br />