My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2007-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:22:53 PM
Creation date
6/3/2020 9:52:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2010
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2007-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
388
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPASER CONTAINMENTPODC) TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descrintion Diso # 7 Dist) # 8 Dist) # 9110 Disn # 11112 <br />UDC manufacturer <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />UDC material <br />Steel <br />Steel <br />Steel <br />Steel <br />UDC depth (inches) <br />9 <br />9 <br />9 <br />9 <br />Height from UDC bottom to highest <br />piping penetration <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />Height from UDC bottom to lowest <br />electrical penetration <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Float <br />Float <br />Was sensor removed for testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />6 <br />6 <br />6 <br />6 <br />Wait time for water level to stabilize (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Test start time <br />11:38 AM <br />12:19 PM <br />12:19 PM <br />12:19 PM <br />Initial Probe Reading <br />0.7382 <br />0.2878 <br />0.7541 <br />0.5931 <br />Test end time <br />11:53 AM <br />12:34 PM <br />12:34 PM <br />12:34 PM <br />Final Probe Reading <br />0.7378 <br />0.2875 <br />0.7536 <br />0.5922 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (t 0.0000 inches) <br />-0.0004 <br />-0.0003 <br />-0.0005 <br />-0.0009 <br />Pass/Fail threshold (10.0020 inches /: Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />PASS <br />Comments: <br />© 2006 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.