My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2011-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:27:40 PM
Creation date
6/3/2020 9:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2016
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2011-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
370
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> As <br /> ,NIFIED PROGRAM CONSOLIDATED FOIW t <br /> ANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> I� <br /> (two/pages per tank) <br /> Page_of <br /> TYPE OF ACTION ❑1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ® 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 FACILITY ID: <br /> NELLA Oil Company LLC#427 <br /> LOCATION WITHIN SITE(Optional) 431 <br /> Underground Storage Tanks south of building <br /> I.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings,and landmarks shall be submitted to the local <br /> agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK C3 Yes 0 No 434 <br /> 42702 Trusco If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/ O) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 10,000 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 430 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® 1. MOTOR VEHICLE FUEL ❑ la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If marked complete Petroleum Type) ❑1b. PREMIUM UNLEADED ❑3. DIESEL [16. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ®1c. MIDGRADE UNLEADED C]4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑4. HAZARDOUS WASTE Plus Unleaded 89 Octane 86290-81-5 <br /> (Includes Used Oil) <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL [:13.SINGLE WALL WITH ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER [195. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT [:199. OTHER <br /> TANK MATERIAL-primary tank ❑ 1. BARE STEEL ❑3. FIBERGLASS I PLASTIC [15. CONCRETE ❑95. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ®4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE W/ ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) 100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑5. CONCRETE [195. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL ®4.STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> ❑5. CONCRETE ❑10.COATED STEEL <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑ 1 MANUFACTURED CATHODIC®3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 449 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENTNEAR INSTALLED 452 <br /> (Check all that apply) ® 1 SPILL CONTAINMENT 1998 yes ❑ 1 ALARM ®3 FILL TUBE SHUT OFF VALVE <br /> ®2 DROP TUBE 1998 yes ❑2 BALL FLOAT ❑4 EXEMPT <br /> ®3 STRIKER PLATE 1998 ms <br /> - <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> +(SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> REMAINING <br /> gallons ❑Yes ❑ No <br /> I IPr.F /1/QA ravicarfl Fnrmarly GWRr'R Fnrm R <br />
The URL can be used to link to this page
Your browser does not support the video tag.