Laserfiche WebLink
r <br /> 0 • <br /> San Joaquin County DIRECTOR <br /> Environmental Health Department Linda Turkatte, RENS <br /> ASSISTANT DIRECTOR <br /> 1868 E Hazelton Avenue AKaseyFoley, REHS <br /> ` Stockton, California 95205 <br /> • PROGRAM COORDINATORS <br /> CP Robert McClellon, REHS <br /> �<<F0` Website: www.sjcehd.com Jeff Carruesco, RENS,RDI <br /> Phone: (209)468-3420 Rodney Estrada, REHS <br /> Fax: (209)464-0138 Willy Ng,REHS <br /> January 03, 2017 <br /> VERONICA FREITAS <br /> WALTON ENGINEERING, INC. FILE C <br /> P.O. BOX 1025 <br /> WEST SACRAMENTO, CA 95691 <br /> Re: NELLA OIL#427 SR0076512 <br /> 3300 WATERLOO RD. <br /> STOCKTON, CA 95205 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br /> application for a permit to replace the 87 FE Petro leak detector with a VMI leak detector on the <br /> underground storage tank (UST) system at the above noted address. This work was completed on <br /> December 28, 2016. The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Stacy Rivera at (209)468-3440 to arrange the following appointments (a 48-hour notice is <br /> required for inspection appointments). Please be aware that inspections for emergency work must be <br /> scheduled within five days of permit approval. <br /> • Leak detector test: Leak detector must be tested to confirm that the device can detect a leak of 3 <br /> gallons per hour at 10 psi. <br /> 4. If concrete will be broken near the tank, a secondary containment test must be performed on the <br /> tank once concrete is poured in accordance with the manufacturer's guidelines. <br /> 5. Any individual performing the work of a service technician must meet the following qualifications: <br /> a. Possess or be employed by a person who possesses one of several permissible valid, current <br /> contractor's licenses issued by the Contractors State License Board (may be issued to the <br /> installation company), or a Tank Tester's license issued to the individual by the State Water <br /> Board, and <br /> b. Possess or work under the direct and personal supervision of an individual physically present at <br /> the work site who possesses a valid, current California UST Service Technician certificate issued <br /> by the International Code Council (ICC), and <br /> c. Possesses a valid, current certificate of training from the manufacturer(s) of the component(s) <br /> being tested, repaired, or serviced. <br />