COMPLIANCE INFO_2011-2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2011-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:27:40 PM
Creation date
6/3/2020 9:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2016
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2011-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
370
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SET-UP REPORT (Page 2) <br /> T 4:DIESEL — <br /> LEAK TEST METHOD OUTPUT RELAY SETUP <br /> PRODUCT CODE 4 - - - - - - - - - - - - - - - - - - - - - - - - <br /> THERMAL COEFF :.000450 TEST ON DATE : ALL TANK <br /> TANK DIAMETER 96.00 OCT 10, 2003 R 1 :87 <br /> TANK PROFILE I PT START TIME : DISABLED TYPE: <br /> FULL VOL 12000 TEST RATE :0.20 GAL/HR STANDARD <br /> DURATION : 2 HOURS NORMALLY CLOSED <br /> FLOAT SIZE: 3.0 IN. TST EARLY STOP:DISABLED <br /> WATER MINIMUM 0.000 LIQUID SENSOR ALMS <br /> LEAK TEST REPORT FORMAT 1. 4:FUEL ALARM <br /> WATER WARNING^ 1 .0 NORMAL L 4:SENSOR OUT ALARM <br /> HIGH WATER LIMIT: 2.0 L 4:SHORT ALARM <br /> WATER ALARM FILTER: LOW <br /> LIQUID SENSOR SETUP R PE: DIESEL <br /> TYPE: <br /> MAX OR LABEL - - - - - - - - - - - - E <br /> STANDARD <br /> VOLUME 12000 <br /> L I :RED DIESEL ANNULAR NORMALLY CLOSED <br /> HIGH PRODUCT TRI-STATE (SINGLE FLOAT) <br /> % MAX 95.0 CATEGORY : ANNULAR SPACE LIQUID SENSOR ALMS <br /> (GALLONS) 11400 L 2:FUEL ALARM <br /> L 2:SENSOR OUT ALARM <br /> OVERFILL LIMIT L 2:RED DIESEL STP SUMP L 2:SHORT ALARM <br /> MAX : 90'0 TRI-STATE (SINGLE FLOAT) <br /> (GALLONS) 10800 CATEGORY : STP SUMP R 3:DIESEL <br /> TYPE: <br /> DELIVERY LIMIT STANDARD <br /> MAX 10.0 L 3:87 ANNULAR NORMALLY CLOSED <br /> (GALLONS) 1200 TRI-STATE (SINGLE FLOAT) <br /> LOW PRODUCT CATEGORY : ANNULAR SPACE LIQUID SENSOR ALMS <br /> VOLUME 1000 L 6:FUEL ALARM <br /> LEAK ALARM LIMIT: 99 L 6:SENSOR OUT ALARM <br /> SUDDEN LOSS LIMIT: 99 L 4:87 STP SUMP L 6:SHORT ALARM <br /> TANK TILT 0.00 TRI-STATE (SINGLE FLOAT) <br /> PROBE OFFSET 0.00 CATEGORY : STP SUMP SMARTSENSOR SETUP <br /> SIPHON MANIFOLDED TANKS L 5:DIESEL ANNULAR s 1:PRESSURE <br /> TO: NONE TRI-STATE (SINGLE FLOAT) CATEGORY VAPOR PRESSURE <br /> LINE MANIFOLDED TANKS CATEGORY : ANNULAR SPACE <br /> Tri: NONE s 2:VAPOR VALVE <br /> CATEGORY VAPOR VALVE <br /> LEAK MIN PERIODIC: 0% L 6:DIESEL STP SUMP s 8:ATM P <br /> 0 TRI-STATE (SINGLE FLOAT) CATEGORY ATM,P SENSOR <br /> CATEGORY STP SUMP <br /> LEAK MIN ANNUAL 01% PMC SETUP <br /> 0 <br /> PMC VERSION: 01 .04 <br /> PERIODIC TEST TYPE VAPOR PROCESSOR TYPE <br /> STANDARD VEEDER-ROOT POLISHER <br /> ANNUAL TEST FAIL <br /> ALARM DISABLED ANALYSIS TIMES <br /> PERIODIC TEST FAIL TIME: 10:00 AM <br /> ALARM DISABLED DELAY MINUTES: 1 <br /> GROSS TEST FAIL SOFTWARE REVISION LEVEL <br /> ALARM DISABLED VERSION 333.04 <br /> SOFTWARE# 346333-100-E <br /> ANN TEST AVERAGING: OFF CREATED - 13.06.07.08.25 <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF FWARE MODULE <br /> RE <br /> C EI V E p SYSTNO EMTFEATURES:PERIODIC IN-TANK TESTS <br /> TNK TST SIPHON BREAKOFF ANNUAL IN-TANK TESTS <br /> DELIVERY DELAY 5 MIN JAN 0 4 2016 <br /> PUMP THRESHOLD 10.00% <br /> ENVIRONMENTAL <br /> HEALTH DEPARTMENT <br /> '02015 Watton Engineering,Inc. <br />