My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1997
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_1986-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 3:55:24 PM
Creation date
6/3/2020 9:52:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1997
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_1986-1997.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NDE'S VPLT COMPUTERIZED TANK TESTING SYSTEM Patent Pending <br />PRECISION UNDERGROUND TANK TESTING RESULTS AND CERTIFICATION <br />PAGE 1, GENERAL REPORT FORM - Copyright 1985 <br />NDE TECHNOLOGY, INC. PROPRIETARY <br />TEST DATE: 12/06/89 <br />1. Owner of storage tanks <br />Company Representative <br />Title <br />2. Mailing address of owner <br />3. Phone of owner <br />4. STATION NUMBER <br />Location and address of <br />the tanks <br />Phone number <br />Regulatory Agency <br />CHEVRON USA <br />M.L. Farrar <br />Senior Marketing Assistant <br />P. 0. Box 5004 <br />San Ramon, CA 94583-0804 <br />(415) 842-9624 <br />-90 W10 <br />4400 Waterloo Rd. <br />Stockton, CA. 95205 <br />(209) 931-2186 <br />County of San Joaquin <br />5. <br />TANK DESIGNATION OR ID # <br />Supreme <br />6. <br />Date each tank was tested <br />12/06/89 <br />7. <br />The name of the test method <br />VPLT COMPUTERIZED TANK TESTING SYSTEM <br />8. <br />Business name of tank <br />testing company <br />WESTERN AMERICA TANK TESTING, INC. <br />9. <br />Mailing address of tank <br />3131 FAIRHAVEN DRIVE <br />testing company <br />BAKERSFIELD, CA 93308 <br />10. <br />Person conducting test <br />Stephen Frasch (TECHNICIAN) <br />and completing report <br />11. <br />Station Operator or <br />Andy Hatfield <br />manager <br />12. <br />Phone number <br />(209) 931-2186 <br />13. <br />Owner name and <br />CHEVRON USA <br />title <br />14. <br />Capacity of the tank <br />10,000'gal�ons <br />15. <br />Present or past contents <br />Supreme <br />�� t <br />16. <br />Tank construction material <br />Steel <br />...',t!TAI mo+F.reI E Y E <br />17. <br />Testing fluid <br />Supreme <br />18. <br />(a) THE UNDERGROUND STORAGE <br />TANK SYSTEM CERTIFIED TIGHT AT PRODUCT <br />HEIGHT EQUAI, TO THE GRADE <br />LEVEL. Yes. <br />(b) Allowable leak resolution <br />of instrumentation or allowable change <br />per California Administrative <br />Code Title 23 Waters, Chapter 3 <br />Water Resources Control Board <br />Subchapter 16 Untderground Storage <br />Regulations, Part 2643 (b), <br />Page 4.14; 0.05 gallons per hour. <br />*** <br />(c) MEASURED HOURLY CHANGE: <br />LOSS (+) OR GAIN (-) GALLONS OR <br />NUMERICAL LEAK RATE IS: <br />+0.016 Gal/Hr. <br />------------------------------------------------------------------ <br />This measurement is within <br />the legal limits as defined in (b). <br />NDE TECHNOLOGY, INC. PROPRIETARY <br />WATT INC. 3131 FAIRHAVEN DRIVE, BAKERSFIELD, CA 93308 (805) 322-9827 <br />
The URL can be used to link to this page
Your browser does not support the video tag.