My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_1997-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 3:52:47 PM
Creation date
6/3/2020 9:53:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2006
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_1997-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
535
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />Page 6 of * 7 <br />8. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sums ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Te -t F.auinment Used: Wavne Perry Inc. See Attached Results Equipment Resolution:.OW7" <br />Comments — (include <br />ormatton on repairs <br />e:4. <br />made prior to testing, and recommended <br />Chevron #99840 <br />4344 Waterloo Rd. <br />Stockton, CA, 95215 <br />N04770 — SS 989 Testing <br />tests <br />Sump <br />Sump <br />Sump <br />Sump <br />Sump Diameter: <br />" <br />Sump Depth: <br />" <br />Sump Material: <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />„ <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Portion of Sump Tested' <br />2" ABOVE HIGHEST <br />PENETRATION <br />2" ABOVE HIGHEST <br />PENETRATION <br />2" ABOVE HIGHEST <br />PENETRATION <br />2" ABOVE HIGHEST <br />PENETRATION <br />Wait time between applying water <br />and starting test: <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: <br />Initial Reading (RD: <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />Change in Reading (RF -RD: <br />Pass/Fail Threshold or Criteria: <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />Is there a sensor in the sump? ® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA <br />Mom <br />® Yes ❑ No ❑ NA <br />Does sensor alarm when either <br />product or water is detected? <br />❑ Yes ❑ No RNA <br />❑ Yes ❑ No ® NA ' <br />' ❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />Was sensor removed for Testing? <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />N Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Comments — (include <br />ormatton on repairs <br />e:4. <br />made prior to testing, and recommended <br />Chevron #99840 <br />4344 Waterloo Rd. <br />Stockton, CA, 95215 <br />N04770 — SS 989 Testing <br />tests <br />
The URL can be used to link to this page
Your browser does not support the video tag.