My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_1997-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 3:52:47 PM
Creation date
6/3/2020 9:53:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2006
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_1997-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
535
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING PROCEDURES DOUBLE CONTAINED PIPING <br />CONTINUOUS ELECTRONIC MONITORING SUMPS <br />DOUBLE CONTAINED PIPING <br />INTERSTITIAL SPACE MONITOR: _VAPOR X LIQUID _NONE <br />SUMP MONITOR: VAPOR X LIQUID _NONE <br />EQUIPMENT AT THIS FACILITY IS: VEEDER-ROOT TLS -350 <br />All double contained piping is continuously monitored electronically by a system that can sense a <br />leak at more than one location. A line pressure monitor capable of sensing a pressure loss in the <br />system and activating a valve to disable the flow of product through the lines also monitors <br />pressurized pipes. The product lines are sloped down towards the tank, and if the pressure sensor <br />is activated any liquid in the annular space will flow backwards toward the sump area. There is a <br />discriminating sensor in the sump area that detects any liquid and hydrocarbons present there. The <br />system has both visible and audible alarms that are activated when there is liquid in the sump or <br />detected in the secondary containment with positive shut down for high liquid and hydrocarbons. <br />RESPONSE PLAN <br />If the system goes into the alarm mode, the Operator or his designate will check the alarm panel to <br />verify that there is a leak condition and then silence the audible alarm. The Operator or his <br />designee will immediately contact Chevron dispatch and advise them of the situation so that they <br />can contact the appropriate personnel who will follow the instructions outlined in the "Leak <br />Response Plan", which is part of your Hazardous Material Management Plan. All follow up will be <br />completed within the month the problem occurred. <br />The tank monitor alarm will be visually monitored daily. The Operator or an employee appointed by <br />the Operator will follow the same procedures as outlined for monitoring the double contained <br />product tanks. <br />PREVENTATIVE MAINTENANCE <br />The monitoring equipment shall be inspected and certified annually. Maintenance will be performed <br />annually or as needed. All work performed to the monitoring system will be in accordance to the <br />manufacturers recommendations. <br />TRAINING <br />Tank operators are trained on the proper operations of the monitoring equipment per the <br />manufacturer's instructions. <br />Chevron Maintenance Dispatch (24 Hour) 1-800-423-3528 <br />
The URL can be used to link to this page
Your browser does not support the video tag.