My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 1:18:05 PM
Creation date
6/3/2020 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2012-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I V <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC)TESTING JAN <br /> Test Method Developed By: E]UDC Manufacturer El Industry Standard F1 Profe"(W <br /> (Spec)c ify) 'Yk-t r,�M_m A A <br /> ❑Other( M K!E N <br /> Test Method Used: ❑Pressure E]Vacuum JZI Hydrostatic <br /> El Other(Specify) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br /> UDC# 3/4 UDC# 5/6 UDC# 7/8 <br /> UDC Manufacturer: <br /> UDC Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 30" 30" 30" 30" <br /> Height from UDC Bottom to Top 10,, 10" 101, 10" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 5.1 5" 5" 5" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Fair Fair Fair Fair <br /> testing: <br /> Portion of UDC Tested' Above highest penetration Above highest penetration Above highest penetration Above highest penetration <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both N/A N/A N/A N/A <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- 0 Yes 0 No 0 NA 0 Yes El No IONA 0 Yes 0 No IZI NA r7l Yes 0 No [71 NA <br /> safe shutdown?* <br /> Was fail-safe verified to be 2 Yes E]No [2]NA El Yes n No 171 NA 0 Yes [I No IZI NA F1 Yes El No [Z]NA <br /> o erational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes 15 minutes 15 minutes <br /> starting test <br /> Test Start Time: 12:42pm Visual Fail Visual Fail 12:42pm <br /> Initial Readin (Ri): 4.3549 Inches Inches Inches 0.3301 Inches <br /> Test End Time: 12:57pm 12:57pm <br /> Final Reading(RF): 4.3549 Inches Inches Inches 0.3301 Inches <br /> Test Duration: 15 mins 15 mins 15 mins 15 mins <br /> Change in Reading(RF-R,): 0.0000 0.0000 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: 2 Pass Fl Fail [] Pass []Fail C] Pass []Fail 2 Pass []Fail <br /> Was sensor removed for testing? 0 Yes 0 No El NA ZI Yes 0 No El NA 171 Yes El No E]NA Z Yes []No Ej NA <br /> Was sensor properly replaced and [21 Yes El No []NA (Z Yes E]No n NA Z Yes E]No E]NA Z Yes E]No Fl NA <br /> verified functional after test <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> UDC'S 3/4 & 5/6 Visual Fails - lost 6" water in 15 min - need to replace penetrations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.