My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 1:18:05 PM
Creation date
6/3/2020 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2012-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> DEC 2 12015 <br /> 4. TANK ANNULAR TESTING ENVIRONMENTAL HEALTH <br /> Test Method Developed By: E]Tank Manufacturer FZ]Industry Standard E]Professional WAROUSERVICES <br /> E)Other(Specify) <br /> Test Method Used: E]Pressure R]Vacuum E]Hydrostatic <br /> El Other(Specify) <br /> Test Equipment Used:See attached testing procedures Equipment Resolution: inHg <br /> Tank#87 Tank# 91 Tank# Tank# <br /> Is Tank Ex <br /> emp <br /> t From Testing?' OYes ZNo [ Yes DNo OYes :No :Yes :No <br /> TankCapacity: <br /> Tank Material: Fiberglass Fiberglass <br /> Tank Manufacturer: <br /> Product Stored: 87 91 <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes 15 minutes 15 minutes <br /> starting test: <br /> Test Start Time: 9:53am 9:40am <br /> Initial Reading(RI): 10 inHg 10 inHg inHg inHg <br /> Test End Time: 10:53am 10:40am <br /> Final Reading(RF): 10 inHg 10 inHg inHg inHg <br /> Test Duration: 1 hour 1 hour 1 hour 1 hour <br /> Change in Reading(RF-RI): 0 0 <br /> Pass/Fail Threshold or Criteria: 0 0 0 0 <br /> Test Result: 21 Pass 0 Fail 2 Pass 0 Fail 0 Pass 0 Fail OFail <br /> Was <br /> 0� ' <br /> Was sensor removed for testing? OYes ONo [INA Elyes ONo EINA [Dyes ONo [INA Oyes ONO EINA <br /> Was sensor properly replaced and ®yes []No []NA [Z]Yes [:]No [INA [DYes No ONA [21Yes E]No EINA <br /> verified functional after testing? I <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23,Section 2637(a)(6)) <br />