My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 1:18:05 PM
Creation date
6/3/2020 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2012-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> DEC 2 1 2015 <br /> 6. PIPING SUMP TESTING ONMENIM H ? <br /> Test Method Developed By: ❑Sump Manufacturer ❑✓ Industry Standard ❑Professional $ _ VIC <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ❑✓ Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br /> mffmmmm <br /> Sump# 87 Sump# 91 Sump# Sump# <br /> Sump Diameter: 48" 48" <br /> Sump Depth: 72" 75" <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 12" 12" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 27" 28" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Fair Fair Fair Fair <br /> Portion of Sump Tested' Above highest penetration Above highest penetration Above highest penetration Above highest penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No [DNA ❑Yes ❑No ✓❑NA [:]Yes[:] No ❑✓NA ❑Yes Flo OqA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A I N/A I N/A <br /> Is system programmed for fail-safe ❑yes ❑No ❑✓NA ❑Yes ❑No [Z]NA ❑Yes[] No[ZINA ❑Yes ❑No [ZINA <br /> shutdown?' <br /> Was fail-safe verified to be ®Yes ❑No [Z]NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 minutes 15 minutes 15 minutes 15 minutes <br /> test: <br /> Test Start Time: 11:01 am 11:01 am <br /> Initial Reading(R,): 1.04094 Inches 0.77260 Inches Inches Inches <br /> Test End Time: 11:16am 11:16am <br /> Final Reading(RF): 1.04141 Inches 0.77311 Inches Inches Inches <br /> Test Duration: 15 mins 15 mins 15 mins 15 mins <br /> Change in Reading(RF-RI): 0.00047 0.00051 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: OPass ❑Fail [DPass []Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> Was sensor removed for testing? [Z]Yes []No []NA ❑✓Yes ❑No ❑NA [D Yes ❑No ❑NA [D Yes []No [INA <br /> Was sensor properly replaced and [Z]Yes [-]No []NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑✓ Yes ❑No []NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.