T <br /> Dry fitting secondary Vent piping — <br /> containment systems Do not use fiberglass pipe to <br /> (Cont.) support the weight of heavy items in Permanent <br /> a line such as valves,strainers and structure4P.Pe <br /> steel riser pipes.When containing <br /> vent piping,do not use fiberglass Steel pipeclavent or containment piping to <br /> Fig.7-12.Support risers by attaching support the steel riser pipes:the <br /> them directly to structure walls. weight of the steel risers may <br /> prevent good bonds in the fiberglass Stlines and result in leaks.Support the <br /> risers by attaching them directly to <br /> structure walls. Dualoy 3000/L <br /> Bonding containment Adhesives for containment piping <br /> piping Two different amine-cured epoxy-resin adhesives are used to install Ameron contain- <br /> ment piping.Ameron B20 adhesive is used for 3,3'/2,4 and 6-inch containment pipe <br /> c Apply a heavy and fittings.RP34C is used for 6-inch systems using older fittings. <br /> layer or bead <br /> Bonding and testing contained rimapipingry <br /> of adhesive to <br /> shaded areas Bond the primary only after the containment pipe has been placed over it and all <br /> adjustments have been made for clearance and interference. <br /> . Follow standard adhesive procedures.Do not disturb the primary lines before <br /> Install Inside the adhesive cures. <br /> rivets or rests <br /> ................... <br /> and bolts first Primary system bonds must be visually inspected or soap tested before installing <br /> ................... <br /> ................... <br /> contai nment fittings. <br /> Sealing containment piping <br /> Holes on some Bond containment only after primary lines have been tested and inspected. <br /> older containment All bonding surfaces must be free from water,soap,oil,grease,dirt and the like <br /> G' fittings may need to 9 P. <br /> be enlarged using a and should be lightly sanded before applying adhesive. <br /> 17/64 drill lit before <br /> inserting rivets Take care that each leg of the containment pipe goes into the fitting straight and <br /> Fig.8-1. Containment fittings seal is not disturbed until the adhesive has cured. <br /> effectively only if the shaded areas Assembly of 3,3'/2,4 and 6-inch containment <br /> between the holes in the flanges and the <br /> inside are well covered with adhesive. Apply a uniform,heavy coating or heavy bead of adhesive to the inner half of <br /> Adhesive applied to the outer half of containment fittings flanges(Fig.8-1),to the sanded radius of the fitting where <br /> containment fitting flanges will serve no <br /> purpose unless the holes themselves are the pipe will fit,and to the outside of the containment pipe.Apply adhesive to <br /> sealed.Forthis reason,and to conserve both half-shells. <br /> adhesive,it suffices to apply adhesive <br /> only to the inner half of the flanges. Put the containment fitting around the containment pipe carefully.Make sure the <br /> pipe is not cocked or misaligned in the fitting. <br /> • The recommended method of joining 3,31h and 4-inch Dualoy containment <br /> fittings is by means of rivets.Rivetted closure is cleaner,more effective and <br /> 1-—————————————'1 much faster than closure with nuts and bolts.The compressed air-driven <br /> The sole purpose of rivets and bolts is 1 Ameron Rivetool and appropriately sized rivets are available from Ameron or <br /> I to hold containment fitting halves I from your Ameron distributor.Use wing nuts or conventional bolts to close <br /> together while the adhesive cures. <br /> I I 6-inch containment fittings. <br /> I The performance of joined and cured <br /> 1 Ameron fiberglass pipe systems 1 Insert a rivet into each of the holes in the fitting. <br /> 1 depends in no way on rivets,bolts or 1 - Keep the upper stem of the rivet clean to avoid the accumulation of adhesive in <br /> any other metallic closure devices. the end of the Rivetool. <br /> I Moreover,the UL/ULC listing for I r®®®®®®®®_I <br /> Dualoy3000/L secondary 1 After inserting the rivets,hold the two fitting halves I Follow all instructions and I <br /> containment piping is the result of 1 together firmly with three or four C-clamps.It is I safety precautions I <br /> 1 tests conducted after the adhesive 1 always best to insert the rivets before applying the I provided with the Rivetool. <br /> has cured and all rivets and bolts clamps as the rivets serve to line up the holes. L————————-� <br /> 1 have been removed. 1 Attempting to rivet containment fittings without using C-clam s can result <br /> in substandard joints. <br /> 10 <br />