Laserfiche WebLink
10 SUtl1P penetrations sufficient length of primary pipe to accommodate both the closure pieces and the <br /> (comn , fiberglass bell x female threaded adapter which terminates the primary. <br /> To install 3 x 2 reducing closures,sand the sump fitting,the exterior of the primary pipe <br /> for about 1'/2 inches where the small end of the closure pieces will fit(Fig.10-4),and <br /> the bonding surfaces of the closure pieces(Fig.7-6).Apply liberal amounts of adhesive <br /> to the sanded areas and bolt the closure halves together. <br /> The containment system annular space can also be sealed off and isolated from the <br /> sump by means of special sump penetration fittings that permit direct connection of <br /> 11/2 or 2-inch flex <br /> 42 to 48- connectors to the <br /> Fig. Sand the bonding ftjBy otters inch riser <br /> 9 9 penetration fittings <br /> surfaces of the sump penetration <br /> fitting,the primary pipe,and the - themselves on the <br /> reducing closure pieces before _ inside of the sump. <br /> applying B20 adhesive. This configuration <br /> provides more space <br /> Sand shaded areas in the sump.These <br /> fittings also <br /> 42 to 48-inch riser incorporate tapered <br /> By others <br /> Annular space female bell ends on <br /> I <br /> Fig.10-5.Sump penetration fittings arei/ open ( the other end,thus <br /> available from the factory with 11h-and <br /> 2-inch NPT female threads on the inside permitting direct <br /> 91 <br /> and 2-inch female tapered bell ends on bonding of 2-inch <br /> the outside that permit direct connection f primary pipe to the <br /> of flex connectors and product lines. Anrularspace <br /> sealed at the penetration fittings <br /> factory on the outside of the <br /> sump. <br /> On the outside of the sump,join the containment pipe to the penetration fitting with the <br /> following: <br /> 1) Full-length 3-inch containment couplings;or <br /> 2) Half-length 3-inch containment couplings as shown in Fig.10-7;or <br /> 3) 3'h x 3-inch reducing couplings,when 31h-inch containment pipe is used directly <br /> adjacent to the sump. <br /> Byothers 42 to 48-inch riser <br /> Annular space j <br /> open <br /> Fig.10-6.The sump penetration <br /> fittings shown in Fig.10-5 are also <br /> available with factory-installed <br /> monitoring ports that can be used in <br /> place of the ported reducing closure f <br /> shown in Fig.10-3. Annular space sealed <br /> f <br /> Nipple and 45'elbow <br /> installed at factory <br /> 42 to 48-inch riser <br /> Fig.10-7.Join containment piping to - <br /> sump penetration fittings by means of i <br /> containment couplings or 31/2 x 3-inch —• <br /> containment reducing couplings if _ _ ____ ______- <br /> 31/2-inch containment pipe is used <br /> directly adjacent to the sump. <br /> 14 <br />