--WED PROGRAM CONSOLIDATED FOR <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (Two pages per tank) <br /> Page I of 2 <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (utak one item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (specify reason) (specify reason) ® 8.TANK REMOVED <br /> BUSINESS NAME(same as FAcnxry NAME or DBA-Doing Business As) 3. 1 FACILITY ID: 1• <br /> Pacific Bell <br /> LOCATION WITHIN SITE(optional) 431. <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432. TANK MANUFACTURER 433• COMPARTMENTALIZED TANK ❑Yes ® No 434. <br /> 01948 Modem Welding If"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435• TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 1991 4,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438. <br /> H.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE aao. <br /> ® 1. MOTOR VEHICLE FUEL ❑1a REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If checked,complete Petroleum Type) ❑lb. PREMIUM UNLEADED ®3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑lc. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441. CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> M.TANK CONSTRUCTION <br /> TYPE OF TANK [11. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL 4. SINGLE WALL IN A VAULT 0 99. OTHER <br /> TANK MATERIAL-primary tank ®1. BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑5. CONCRETE ®95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC W/100%METHANOL <br /> TANK MATERIAL-secondary tank [11. BARE STEEL ❑3. FIBERGLASS/PLASTIC [18. FRP COMPTIBLE W/100%METHANOL ❑95.UNKNOWN 4a5. <br /> (Check one item only) ❑2. STAINLESS STEEL ®4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) [110. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 0 1.RUBBER LINED 0 3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING [:12.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC ❑3.FIBERGLASS REINFORCED PLASTIC ®95.UNKNOWN 448, DATE INSTALLED 4a9, <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> IfApplicable) 2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. 1 OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) ®1.SPILL CONTAINMENT _1991 ®1.ALARM 1991 ®3.FILL TUBE SHUT OFF VALVE 1991 <br /> ®2.DROP TUBE _1991_ ❑2.BALL FLOAT_ ❑4.EXEMPT <br /> ❑3.STRIKER PLATE 1991 <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> 4. STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> 1SIR)+BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 416' TANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPCF hwfwrc-b(1/99)-1/4 http://www.unidocs.org Rev.02/16/00 <br />