My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:20:31 PM
Creation date
6/3/2020 9:53:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
408
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix V1 <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at gov .) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All.1urisdictions Within the State of California <br /> Authority Cited. Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Code ofRegulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. Acopy of this form must be provided to the tank system owner/operator. The <br /> owner/operator must submit a copy ofthis form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Pacific Bell Telephone Co.dba AT&T California Building No.: UE020 <br /> Site Address: 124 W. ELM ST. City: Lodi Zip: 95240 <br /> Facility Contact Person: Gary Chi mienti Contact Phone No.: (925)468-8103 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 plus Date of Testing/Servicing: 4/5/2013 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> TankID: UE020U001 Tank ID: UE020A003 <br /> R' In-Tank Gauging Probe. Model: 847390-107/439514 j In-Tank Gauging Probe. Model: <br /> R_ Annular Space or Vault Sensor. Model:794390-420/441672 Annular Space or Vault Sensor. Model: 794380-344 844409 <br /> Piping Sump/Trench Sensor(s). Model: 794380-208/685112 F Piping Sump/Trench Sensor(s). Model: <br /> F Fill Sump Sensor(s). Model: 794380-208/675586 Fill Sump Sensor(s). Model: <br /> F Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: 790091-001 H Tank Overfill/High-Level Sensor. Model: <br /> R_ Other(specify equipment type and model in Section E on Page 2). Other(specify equipment type and model in Section E on Page 2). <br /> ...... ftmwwmwmm <br /> i Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: F In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Sp e or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> f Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> F Tank Overfill/High-Level Sensor. Model: Tank Overfill/High Level Sensor, Model: <br /> Other(specify equipment type and model in Section E on Page 2). 2).. <br /> Other(specify equipment type and model in Section E on Page <br /> Dispenser ID: Dispenser ID: <br /> r Dispenser Containment Sensor(s). Model: i�F Dispenser Containment Sensoqs). Model: <br /> F Shear Valve(s). F Shear Valve(s). <br /> f Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> ........... <br /> i! Dispenser ID: <br /> Dispenser ID: <br /> Dispenser Containment Sensor(s). Model: Dispenser Containment Sen so i(s). Model: <br /> F Shear Valve(s). S hea r Va IN,e(s). <br /> F Dispenser Containment Float(s)and Ch ain(s). I r Dispenser Containment Float(s)and Chain(s). <br /> ................... <br /> ............ <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers' checklists)necessary to verify that this information is correctand <br /> a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports,I have also attached a copy of <br /> the report;(check all that apply) System set-up Alarm history report <br /> Technician Name(print): John Cascio Signature: <br /> Certification No.: B35337 License. No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: 714560-8222 <br /> Testing Company Address: 2131 SOUTTIDUPOW DRIVE,ANAHEIM,CA92806 Date of Testing/Servicing: 4/5/2013 <br />
The URL can be used to link to this page
Your browser does not support the video tag.