Laserfiche WebLink
END GROSS TEST <br />IN—TANK SETUP AUTO—CONFIRM: DISABLED <br />— — — — — — — — — — — — <br />REPORT ONLY: <br />T I:DIESEL TK#UE042U00I DISABLED <br />PRODUCT CODE I TST EARLY STOP:DISABLED <br />THERMAL COEFF :.000450 <br />TANK DIAMETER 120.00 LEAK TEST REPORT FORMAT <br />TANK PROFILE I PT NORMAL <br />FULL VOL 25018 <br />ALARM HISTORY REPORT <br />FLOAT SIZE: 4.0 IN. <br />----- SENSOR ALARM ----- <br />WATER WARNING <br />1.5 <br />L 5:SUPPLY <br />C I:A006 TANK ANNULAR <br />HIGH WATER LIMIT: <br />2.0 <br />TRI—STATE <br />ANNULAR SPACE <br />----- SENSOR ALARM ----- <br />ALARM DISABLED <br />CATEGORY : <br />FUEL ALARM <br />MAX OR LABEL VOL: <br />25018 <br />SEP 9. 2013 11:48 AM <br />OVERFILL LIMIT <br />90% <br />L 6:RETURN <br />LINE TRAN BOX <br />FUEL ALARM - <br />22516 <br />TRI—STATE <br />FUEL ALARM <br />HIGH PRODUCT <br />95% <br />LIQUID SENSOR SETUP <br />SEP 7, 2013 8:01 AM <br />FUEL ALARM <br />23767 <br />DELIVERY LIMIT <br />49% <br />— — — — — — — — — — — — <br />SETUP DATA WARNING <br />SETUP DATA WARNING <br />12500 <br />L I:ANNULAR SPACE <br />SEP 4, 2013 3:22 PM <br />LOW PRODUCT <br />12500 <br />TRI—STATE (SINGLE FLOAT) <br />OTHER SENSORS <br />LEAK ALARM LIMIT: <br />99 <br />CATEGORY : ANNULAR SPACE <br />SUDDEN LOSS LIMIT: <br />99 <br />L 8:TRANS <br />BOX OUTSIDE <br />TANK TILT <br />0.00 <br />TRI—STATE <br />(SINGLE FLOAT) <br />PROBE OFFSET <br />0.00 <br />L 2:FILL SUMP <br />PIPING SUMP <br />TRI—STATE (SINGLE FLOAT) <br />SIPHON MANIFOLDED <br />TANKS <br />CATEGORY : PIPING SUMP <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />L 3:MIDDLE SUMP <br />END <br />T#: NONE <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />LEAK MIN PERIODIC: <br />80% <br />: <br />20014 <br />LEAK MIN ANNUAL <br />Boyo <br />L 4:PIPING SUMP <br />20014 <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />PERIODIC TEST TYPE <br />L 9:HI—LEVEL TNK006 GENI <br />TRI—STATE (SINGLE FLOAT) <br />END CATEGORY : OTHER SENSORS <br />L10:HI LEVEL TNK005 GEN2 <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />LEAK TEST METHOD <br />TEST CSLD ALL TANK L11:GEN1 TNKA006 FLOOR <br />Pd = 95% TRI—STATE (SINGLE FLOAT) <br />CLIMATE FACTOR:MODERATE CATEGORY : OTHER SENSORS <br />STANDARD <br />ALARM HISTORY REPORT <br />L 5:SUPPLY <br />LINE TRAN BOX <br />ANNUAL TEST FAIL <br />TRI—STATE <br />(SINGLE FLOAT) <br />----- SENSOR ALARM ----- <br />ALARM DISABLED <br />CATEGORY : <br />PIPING SUMP <br />C 2:A005 TANK ANNULAR <br />ANNULAR SPACE <br />PERIODIC TEST FAIL <br />L 6:RETURN <br />LINE TRAN BOX <br />FUEL ALARM - <br />ALARM DISABLED <br />TRI—STATE <br />(SINGLE FLOAT) <br />SEP 9, 2013 12:15 PM <br />GROSS TEST FAIL <br />CATEGORY : <br />PIPING SUMP <br />FUEL ALARM <br />ALARM DISABLED <br />SEP 7. 2013 8:05 AM <br />ANN TEST AVERAGING: OFF <br />L 7:PUMP PAN <br />SENSOR <br />SETUP DATA WARNING <br />PER TEST AVERAGING: OFF <br />TRI—STATE <br />(SINGLE FLOAT) <br />SEP 4, 2013 3:22 PM <br />CATEGORY : <br />OTHER SENSORS <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />L 8:TRANS <br />BOX OUTSIDE <br />DELIVERY DELAY 5 MIN <br />TRI—STATE <br />(SINGLE FLOAT) <br />PUMP THRESHOLD 10-00% <br />CATEGORY : <br />PIPING SUMP <br />L 9:HI—LEVEL TNK006 GENI <br />TRI—STATE (SINGLE FLOAT) <br />END CATEGORY : OTHER SENSORS <br />L10:HI LEVEL TNK005 GEN2 <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />LEAK TEST METHOD <br />TEST CSLD ALL TANK L11:GEN1 TNKA006 FLOOR <br />Pd = 95% TRI—STATE (SINGLE FLOAT) <br />CLIMATE FACTOR:MODERATE CATEGORY : OTHER SENSORS <br />