My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2004-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2024 11:02:29 AM
Creation date
6/3/2020 9:53:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2006
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231873_10 E 12TH_2004-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
351
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
amn PROGRAM CONSOLIDATED FOR <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE I A1351 <br /> (Two pages per tank) <br /> w <br /> Page 1 of 2(new tank) <br /> TYPE OF ACTION 1.NEW PERMIT ❑ 4 AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT New 8,000 Gal.Diesel Tank 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specilyreason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(same w FAciLrry NAmE or DBA-Doing Business 3. 1 FACILITY ID: <br /> Pacific Bell <br /> LOCATION V=IIN SITE(Optional) TA o5r5,6-qLA 431. <br /> ................. ......... ................................... ........................................... ............ ........ ........ <br /> .................................. <br /> .......... . ...... <br /> ...>::;;,:;;::..... ........ ..... .. ................... .... <br /> ............ ........... ........... ..... <br /> ........ ....... <br /> ............... ............................ ... ........ .............................. <br /> .......... ... ............ ........ <br /> ............. <br /> ............. <br /> .................... <br /> .............. <br /> . ............ <:;;: <:>:<::»:;:;:;<s:;<:>::;:.....;:.. .... ............... <br /> ................................................. .............. ........ ..................... ..... .. ..... . ............ <br /> .................................................... ... . . . .. ....... .............................................. <br /> ......... ............................... <br /> . ........ <br /> Uagmqy <br /> -.4b,41" -10 th"M <br /> ............... WOW A .*% i 640.w."' 0'. ST �4 ow" ft t. ..... ....... <br /> *- r .��-:............................... <br /> Au <br /> TANK ID# 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK [I Yes Z No 434. <br /> 1103 Modem Welding If"Yes,"complete one page for each compartmad. <br /> DATE INSTALLED 435- TANK CAPACITY IN GALLONS 436- NUMBER OF COMPARTMENTS <br /> (YEAR/MO) 437. <br /> New(probably 2001 8,000 1 <br /> ADDITIONAL DESCRIPTION(For low use only) 438. <br /> ..................................................... ......... ............ ......... ......... <br /> .. ............. ........ . . ........... <br /> . ........... .. ...... ................ .................... <br /> .......................................... <br /> ............... ..... .. ..... ......... ...... <br /> ................ .......... . .. ..... <br /> .............. <br /> ............. <br /> ................. .. <br /> ......... <br /> -�i ............... <br /> ................................... . <br /> ........... <br /> .................. .. ..... ........ . . .. . . ........ <br /> TANK USE 439- PETROLEUM TYPE 440. <br /> t@ 1. MOTOR VEHICLE FUEL 0 Ia. REGULAR UNLEADED 0 2. LEADED 0 5. JET FUEL <br /> (If checked,complete Petroleum Type) ❑lb. PREMIUM UNLEADED IR 3. DIESEL [:16. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑lc. jMGRADEUNLEADED [34. GASOHOL 0 99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hanrdous Materials Inventory page) 441. CAS#(from Hazardous Materials inventory page) 442. <br /> 0 4 HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> 0 95.UNKNOWN <br /> .............................. ....... ....... ......--........... ...... .......... ............ ....................... <br /> ...................... X ......... .. ..... ...a. <br /> . . ....... <br /> ............................................................ <br /> ........................I......... ....... .................. <br /> AAM ........... <br /> .............. .... .... ...................... ......... ...... ........ <br /> ..................... <br /> .......................... ... ...... ...............------- I. .... ........ ........ .. <br /> ........... <br /> .............. ................ .......... . ........... <br /> ............ '..X.:.. ........:... �, ....................... :..., -1.1-......:...-..:,......................:.:.:......�..� <br /> .................................... ... ........... <br /> W .......- -................... .... .....%......... <br /> ........................ :,'' -- ....................... <br /> TYPE OF TANK 1. SINGLE WALL. 3. SINGLE WALL WITH EXTERIOR: 0 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER [195. UNKNOWN <br /> 2. DOUBLE WALL 0 4. SINGLE WALL IN A VAULT Q 99. OTHER <br /> TANK MATERIAL-primary tank MI. BARE STEEL 3. FIBERGLASS/PLASTIC 0 5. CONCRETE 95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL 0 4. STEEL CLAD W/FIBERGLASS 0 8. FRP COMPATIBLE 0 99.OTHER: <br /> REINFORCED PLASTIC(FRP) W1100%METHANOL <br /> TANK MATERIAL-secondary tank [11. BARE STEEL El 3. FIBERGLASS/PLASTIC 8. FRP COMPTIBLE W1100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) C3 2. STAINLESS STEEL 0 4. STEEL CLAD WIFIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> 0 5. CONCRETE <br /> TANK INTERIOR LINING 1.RUBBER LINED 0 3.EPDXY LINING 0 5.GLASS LINING 0 95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING 0 4 PHENOLIC LINING N 6 UNLINED 0 99.OTHER - 1988 <br /> (Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC N 3.FIBERGLASS REINFORCED PLASTIC 0 95.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION [14.RAPRESSED CURRENT ❑99.OTHER 1988 <br /> (If Applicable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) 1.SPILL CONTAINMENT 2001(unconfirmed) 0 1.ALARM (2001) 3.FILL TUBE SHUT OFF VALVE(2001) <br /> 2.DROP TUBE ___.2001(unconfirmed) 0 2.BALL FLOAT(2001) ❑4.EXEMPT <br /> 3.STRIKER PLATE 2001(unconfirmed) <br /> .................... ..................................................... <br /> ..... .............................. .............................. <br /> ...................................... <br /> ............................ <br /> ..........-............................... ........ ... <br /> ......... . ...... ..................................................................... <br /> ........... ...... <br /> .....................- ** - * <br /> ............. .......... ........ <br /> ........................ ........................................ ............... <br /> .......... .... .... .......... <br /> ..............%...............'........,.............. ..... <br /> .............. .................... . ..... ..... ......................................................... <br /> ..... ..... ....... ........... ........ <br /> .............................................. .............................w........... <br /> . ... . ...... .. <br /> ................ <br /> i.al, i ......................... <br /> IF SINGLE WALL TANK 453- IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Checkall that apply) (Check one item only) <br /> 0 1. VISUAL(EXPOSED PORTION ONLY) 0 5.MANUAL TANK GAUGING WrG) 0 1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> 0 2. AUTOMATIC TANK GAUGING(ATG) [3 6.VADOSE ZONE 0 2.CONTINUOUS INTERSTITIAL MONITORING <br /> 0 3. CONTINUOUS ATG 0 7.GROUNDWATER 0 3.MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION [18.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING 0 99. OTHER <br /> ................................... ................................ ....... ..... ..................... <br /> ................-......................... <br /> .......... <br /> .. . . ... ........... <br /> ....... ..... <br /> .*..,. - ... a.. ........ I FEW&AN T. S -PLACE*"*�"" '*'�"���"""" .:..� <br /> ......................... .....:. -.. . ..TAW <br /> ............................. <br /> ............... URKIN <br /> ........... <br /> .............................. .. ... <br /> .................................................................... <br /> .. ................ ........... ...... ............................................................ .. . ... <br /> .. ..... ..... ............-............ .....................................................................I.................,...,.,...........,..........��....�� ..�....�........,......................-.............-...- <br /> ............I...... ...... ................ .. <br /> ............... ................ ... .................... .... ...... <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455- ESTIMATED QUANTITY OF SUBSTANCE REMAINING 457 TANK FILLED WITH INERT MATERIAL? 457. <br /> Currently active gallons ❑Yes [I No <br /> -71,2qlof <br /> UPCF hwfwrc-b(1/99)-1/4 http://www.unidocs.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.