My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 1:30:35 PM
Creation date
6/3/2020 9:53:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231873_10 E 12TH_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Issue Date: November 22, 1995 <br /> Revision Date: March 28,2002 <br /> Veeder-Root <br /> TLS-200,2001, 250,250i, 300, 300C, 3001, 300PC, 350, 350PC, 350R, 350RPC, 350PIus, <br /> Red Jacket ProMax and ProPlus UST ATGS <br /> (Model 8473 Digital Sensing Magnetostrictive Probe) <br /> AUTOMATIC TANK GAUGING METHOD <br /> Certification Leak rate of 0.2 gph with PD = 99% and PFA= 0.1%. <br /> Leak rate of 0.1 gph with PD = 99% and PFA= 1%. <br /> Leak Threshold 0.093 gph for leak rate of 0.2 gph. <br /> 0.071 gph for leak rate of 0.1 gph. <br /> A tank system should not be declared tight if the test result indicates a loss or gain that equals or <br /> exceeds this threshold. <br /> Applicability Gasoline, diesel, aviation fuel. <br /> Other liquids with known coefficients of expansion and density may be tested after consultation with the <br /> manufacturer. <br /> Tank Capacity Maximum of 15,000 gallons. <br /> Tank must be between 50 and 95%full for leak rate of 0.2 gph. <br /> Tank must be minimum 95%full for leak rate of 0.1 gph. <br /> Waiting Time Minimum of 8 hours, 18 minutes between delivery and testing for leak rate of 0.2 gph. <br /> Minimum of 8 hours, 15 minutes between delivery and testing for leak rate of 0.1 gph. <br /> Minimum of 30 minutes between dispensing and testing. <br /> There must be no delivery during waiting time. <br /> Test Period Minimum of 2 hours for leak rate of 0.2 gph. <br /> Minimum of 3 hours for leak rate of 0.1 gph. <br /> Test data are acquired and recorded by system's computer. <br /> Leak rate is calculated from the difference between the first and last data collected. <br /> There must be no dispensing or delivery during test. <br /> Temperature Average for product is determined by a minimum of 5 thermistors. <br /> Water Sensor Must be used to detect water ingress. <br /> Minimum detectable water level in the tank is 0.544 inch. <br /> Minimum detectable change in water level is 0.027 inch. <br /> Calibration Thermistors and probe must be checked and, if necessary, calibrated in accordance with <br /> manufacturer's instructions. <br /> Comments Not evaluated using manifolded tank systems. Therefore, this certification is only applicable when there <br /> is a probe used in each tank and the siphon is broken during testing. <br /> Tests only portion of tank containing product. <br /> As product level is lowered, leak rate in a leaking tank decreases (due to lower head pressure). <br /> Consistent testing at low levels could allow a leak to remain undetected. <br /> EPA leak detection regulations require testing of the portion of the tank system which routinely contains <br /> product. <br /> California regulations require at least one test per month after routine product delivery or when <br /> the tank is filled to within 10%of the highest operating level of previous month. If the 0.1 gph <br /> test is used as a tank tightness test there must be no water present in the backfill (groundwater <br /> must be below the bottom of the tank), the tank must be equipped with an overfill protection <br /> device, and the product level in the tank must be at the overfill protection device set point. <br /> Local agency pre-approval is required. To use the 0.1 gph test as a monthly option see title 23 <br /> CCR Section 2643(b)(2). <br /> Veeder-Root Evaluator: Midwest Research Institute <br /> 125 Powder Forest Dr. Tel: (816)753-7600 <br /> Simsbury, CT 06070-2003 Date of Evaluation: 05/14/93, 03/14/95 <br /> Tel: (860)651-2700 <br />
The URL can be used to link to this page
Your browser does not support the video tag.