My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 1:30:35 PM
Creation date
6/3/2020 9:53:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231873_10 E 12TH_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> For Use By.41I Jin-isdictions Within the State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certificaton or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work A copy of this form must be provided to the tank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> AL General Information <br /> Facility Name: PAC BELL dba AT&T CALIFORNIA Geo Par#: UE058 CLLC Code: TRACCAI I <br /> Site Address: 10 EAST 12TH STREET City: TRACY Zip: 95376 <br /> Facility Contact Person: CONNIE MITCHELL Contact Phone No.: (209)474-4022 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Service: 7/5/07 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment in ected/serviced: <br /> Tank ID: TANK# 1232 Tank ID: <br /> ®In-Tank Gauging Probe Model: 847390-107 ❑In-Tank Gauging Probe: Model: <br /> ®Annular Space or Vault Sensor: Model: 794380 ,y ❑Annular Space or Vault Sensor Model: <br /> ®Piping Sump/Trencb Sensor(s): Model: 794380-352 ❑Piping Sump/Trench Sensor(s): Model: <br /> ®Fill Sump Sensor(s): Model: 794380-352 ❑Fill Sump Sensor(s): Model: <br /> ❑Mechanical Line Leak Detector. Model: N/A ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector Model: N/A ❑Electronic Line Leak Detector Model: <br /> ®Tank Overfill/High-level Sensor. Model: 790091-001 ❑Tank Overfill/High-level Sensor: Model: <br /> ❑Other,SpeSify Specifyequip.t e and model in Section E on Page 2 ❑Other,S2ecjfv a ui . e and model in Section E on Pae 2 <br /> Tank ID: Tank ID: <br /> []In-Tank Gauging Probe: Model: _-_ ❑In-Tank Gauging Probe: Model: <br /> ❑Annular Space or Vault Sensor: Model: ❑Annular Space or Vault Sensor Model: <br /> ❑Piping Sump/Trench Sensor(s): Model: ❑Piping Sump/Trench Sensor(s): Model: <br /> []Fill Sump Sensor(s): Model: ❑Fill Sump Sensor(s): Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High-level Sensor: Model: ❑Tank Overfill/High-level Sensor: Model: <br /> []Other,Specify e ui . e and model in Section E on Pa e 2 ❑Other,S ecif a !i a and model in Section E on Page 2 <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chain(s) ❑Dis enser Containment Floats and Chain s) <br /> Dispenser ID: Dispenser ID: <br /> []Dispenser Containment Sensor(s): Model: []Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> [-]Dispenser Containment Floats and Chains ❑Dis enser Containment Float s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s): Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dis enser Containment Floats and Chain(s)__ ❑Dis enser Containment Float(s)and Chain s <br /> *If the facility contains more tanks or dispensers,copy this forst. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was Inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information(e.g. manufacturers' checklists)necessary to verify that <br /> this information is correct and a Plot Pian showing the layout of monitoring equipment. For any equipment capable of generating <br /> such reports,I have also attached a copy of the report; (check all that apply): 21 System set-up ® Alarm history <br /> report <br /> Technician Name(Print): MICHAEL STRAWN Signature: <br /> Certification No.: A31215 License No.: 588098 <br /> Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No.: (714)560-82 <br />
The URL can be used to link to this page
Your browser does not support the video tag.