My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
12TH
>
10
>
2300 - Underground Storage Tank Program
>
PR0231873
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 1:30:35 PM
Creation date
6/3/2020 9:53:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231873
PE
2361
FACILITY_ID
FA0003956
FACILITY_NAME
PACIFIC BELL - UE058 (TRACY)
STREET_NUMBER
10
Direction
E
STREET_NAME
12TH
STREET_TYPE
St
City
TRACY
Zip
95376
APN
23336922
CURRENT_STATUS
01
SITE_LOCATION
10 E 12TH St
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231873_10 E 12TH_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
527
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br />t ' <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority,Cited:- Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br />prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be <br />provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating <br />UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: SBC GEO PAR # UE -058 CLLC Code: TRAC CAI I <br />Site Address: 10 E. 12TH STREET <br />Facility Contact Person: TOM WILLIAMS <br />City: TRACY <br />Zip: <br />Contact Phone No.: 209-578-7178 <br />Make/Model of Monitoring System: VEEDER ROOT TLS -350 <br />B. Inventory of Equipment TestedlCertified <br />L.. .. 4.. ...a: ..4.. :%„ r.♦ . nn*nt�IcPYVI[`PfI• <br />Date of Testing/Service: 8/4/05 <br />Vf1Gi.11 611E H av aa--- -----»---.-- <br />TankID: 1232 <br />-. —_____ _ __ _______ _— _ _ <br />- <br />Tank ID: <br />ZIn-Tank Gauging Probe: <br />Model: 847390-107 <br />❑In -Tank Gauging Probe: <br />Model: <br />ZAnnular Space or Vault Sensor: <br />Model: 794390-420 <br />[]Annular Space or Vault Sensor <br />Model: <br />ZPiping Sump/Trench Sensor (s): <br />Model: 794380-352 <br />❑Piping Sump/Trench Sensor (s): <br />Model: <br />ZFill Sump Sensor (s): <br />Model: 794380-352 <br />❑Fill Sump Sensor (s): <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />❑Electronic Line Leak Detector <br />Model: <br />❑Electronic Line Leak Detector <br />Model: <br />ZTank Overfill/High-level Sensor: <br />Model: 790091-001 <br />❑Tank Overfill/High-level Sensor: <br />Model: <br />ZOther, S ecif equi a and model in Section E on Page 2 <br />❑Other, Specify equip. t e and model in Section E on Pa e 2 <br />Tank ID: <br />Tank ID: <br />❑In -Tank Gauging Probe: <br />Model: <br />❑In -Tank Gauging Probe: <br />Model: <br />❑Annular Space or Vault Sensor: <br />Model: <br />[-]Annular Space or Vault Sensor <br />Model: <br />❑Piping Sump/Trench Sensor (s): <br />Model: <br />❑Piping Sump/Trench Sensor (s): <br />Model: <br />❑Fill Sump Sensor (s): <br />Model: <br />❑Fill Sump Sensor (s): <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />❑Mechanical Line Leak Detector. <br />Model: <br />❑Electronic Line Leak Detector <br />Model: <br />❑Electronic Line Leak Detector <br />Model: <br />❑Tank Overfill/High-level Sensor: <br />Model: <br />❑Tank Overfill/High-level Sensor: <br />Model: <br />❑Other, Specify e ui a and model in Section E on Pa e 2 <br />❑Other, S ecify e uip. e and model in Section E on Page 2 <br />Dispenser ID: <br />Dispenser ID: <br />[]Dispenser Containment Sensor(s): <br />Model: <br />[]Dispenser Containment Sensor(s): <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Float(s) and Chain(s) <br />❑Dis enser Containment Float(s) and Chain(s) <br />Dispenser ID: <br />Dispenser ID: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Float(s) and Chain(s) <br />[]Dispenser Containment Float(s) and Chain(s) <br />Dispenser ID: <br />Dispenser ID: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑Dispenser Containment Sensor(s): <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Float(s) and Chain(s) <br />❑Dis enser Containment Float(s) and Chain(s) <br />*If the facility contains more tanks or dispensers, copy this torm. incivae mtormanon ror every ranK anu unpunba ai we ia"uny. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that <br />this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating <br />such reports, I have also attached a copy of the report; (check all that apply): Z Systems It Alarm history <br />Al <br />report <br />Technician Name (Print): FRED RIDDLES Signature: <br />Certification No.: 0330 License No.: 588098 <br />Testing Company Name: TAIT ENVIRONMENTAL SYSTEMS Phone No.: (714) 560-8222 <br />
The URL can be used to link to this page
Your browser does not support the video tag.