• the mechanical line leak detector <br /> • (X) is present in <br /> ( ) has been removed from the pipeline (check both if appropriate) <br /> • the waiting time between the last delivery of product to the underground storage tank and <br /> the start of data collection for the test is 0 h. <br /> • the waiting time between the last dispensing of product through the pipeline system and <br /> the start of data collection for the test is 0 h. <br /> • the total data collection time for the test is variable depending on line and product <br /> conditions - evaluation times ranged from 1.8 to 10.9 hours. <br /> • the volume of the product in the pipeline is less than twice the volume of the product in <br /> the pipeline system using in the evaluation, unless separate written justification for <br /> testing larger pipeline systems is presented by the manufacturer, concurred with by the <br /> evaluator, and attached to this evaluation as Attachment 8. <br /> • please give any other limitations specified by the vendor or determined during the <br /> evaluation: <br /> Disclaimer: This test procedure only addresses the issue of the system's ability to detect leaks in <br /> pipelines. It does not test the equipment for safety hazards or assess the operational functionality, <br /> reliability or maintainability of the equipment. <br /> Attachments <br /> Attachment 1 -Description of the System Evaluated <br /> Attachment 2 - Summary of the Performance of the System Evaluated <br /> Attachment 3 - Summary of the Configuration of the Pipeline System(s) Used in the Evaluation <br /> Attachment 4-Data Sheet Summarizing Product Temperature Conditions Used in the Evaluation <br /> Attachment 5 -Data Sheet Summarizing the Test Results and the Leak Rates Used in the Evaluation <br /> Attachment 6 -Data Sheet Summarizing the Test Results and the Trapped Vapor Tests <br /> Attachment 7 - Data Sheet Summarizing the Test Results Used to Check the Relationship Supplied <br /> by the Manufacturer for Combining the Signal and Noise <br /> Certification of Results <br /> I certify that the pipeline leak detection system was operated according to the vendor's instructions. <br /> I also certify that the evaluation was performed according to the procedure specified by the EPA and <br /> that the results presented above are those obtained during the evaluation. <br /> H. Kendall Wilcox President Ken Wilcox Associates, Inc. <br /> (name of person performing evaluation) (organization performing evaluation) <br /> j , 1 1125 Valley Ridge Drive <br /> (signature) (street address) <br /> Anri128, 1998 Grain Valley, MO 64029 <br /> (date) (city,state,zip) <br /> (816)443-2494 <br /> (telephone number) <br /> Pipeline Leak Detection System-Results Form Page 5 of 5 <br />