My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:23:59 AM
Creation date
6/3/2020 9:54:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_1998-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Detection Criterion <br /> 24. What threshold is used to determine whether the pipeline is leaking? <br /> (in the unites used by the measurement system) <br /> 0.068ag 1/h(Annual Mode) ®(in gal/h) <br /> 0.136 ag l/h(MonthlyModef (in gal/h) <br /> 2.5 gal/h(Hourly Modelo (in gal/h) <br /> 25. Is a multiple-test sequence used to determine whether the pipeline is leaking? <br /> ( )yes (If yes, answer the three questions below) <br /> (X)no (If no, skip the three questions below) <br /> How many tests are conducted? <br /> How many tests are required before a leak can be declared? <br /> What is the time between tests? <br /> (Enter 0 if the tests are conducted one after the other.) <br /> Calibration <br /> 26. How frequently are the sensor systems calibrated? <br /> ( )never <br /> ( )before each test <br /> ( )weekly <br /> ( )monthly <br /> ( ) semi-annually <br /> (X)yearly or less frequently <br /> 3Monthly Monitoring for 0.2 gal/h leaks was not tested by KWA,Inc. Tests with leak rates of 0.1 gal/h were <br /> simulated and were detected by the system when the threshold was set at 0.068 gal/h. The system correctly identified <br /> 100%of the 0.1 gal/h leak simulations and it is therefore assumed that the system will correctly identify 0.2 gal/h leaks <br /> using a threshold of 0.136 gal/h. <br /> 4 Three previous evaluations were conducted on versions of the LD-2000 for Hourly Testing. Evaluation <br /> reports written by KWA,Inc.for the following models of the LD-2000 are available from Vaporless Manufacturing: <br /> LD-2000 and LD-2000S, 11/19/90;LD-2000E and LD-2000E-S, 12/11/92;LD-2000T and LD-2000T-S,7/13/93. <br /> Description-Pipeline Leak Detection System Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.