Laserfiche WebLink
• SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sicloy.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> Valero January 28, 2011 <br /> Facility address: UST#/ 5 6 7 <br /> 1001 E. Yosemite Ave., Manteca Product 91 - DSL 87 <br /> Facility contact: Title: Phone: <br /> Charan Dhillon Owner (209) 825-4569 <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> Veeder-Root TLS-350 QxpressurizedauctionOGravityMechanical IKM1-RDetect[:IM2-RPrevElM3-Both <br /> Audible/visual <br /> Inspection type: Designated operator: IGC exp.date: <br /> R- Routine OX Monitoring Certification ❑Installation El other Karen Arnaiz 6/20/11 <br /> On site Service Technician's name: ICC exp.date: Manufacturer's training: <br /> Gavin Williams 8/6/12 VMI x. 3/12/12 VR x. 6/29/12 <br /> VIO <br /> # Code Section HSC=CA Health&SafetyCode;CCR=CA Code of Res lations;V=Violation; RV=Re eat Violation V V <br /> 1 HSC 25284 No permit tooperate <br /> Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711 b Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD x <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plans is not current or approved by the EHD <br /> 6 CCR 2712(i) Monitoring plan, response plan, and/oroperating permit and all conditions not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'/ (Mi) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs,linings,and upgrades for the life of the tank. Monitoring records include:(1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling;(2)monitoring equipment calibration and maintenance records;(3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field;(5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results;(6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January1, 1984 not performed (Mi) <br /> 9 HSG 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST (M1) <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest o rtunit (Mi) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (Mi) x <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi (Mi) <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means (M2) <br /> to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) M2) <br /> 21 HSC 25291(e) Water in 2°containment not removed,analyzed&properly disposed of <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight (Mi) <br /> 22 CCR 2650 hours was not recorded;(e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a 1 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b I CCR 2715(b) Designated operator did not possess a rrent ICG UST SysterrL Operator certification <br /> EHD inspector. Received by: Title: I /n e <br /> EHD 2 2-00 08/13/10 Page 1 UST INSPECTION REPORT <br />