Laserfiche WebLink
1 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited.•Chapter 6.7,Health and Safety Code,Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The ownerloperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: VALERO Bldg.No.: <br /> Site Address: 1001 E.YOSEMITE City: MANTECA Zip: 95336 <br /> Facility Contact Person: BILLA Contact Phone No.: (209) 825-4569 <br /> Make/Model of Monitoring System: TLS 350 Date of Testing/Servicing: 1/20/2010 <br /> B. Inventory of Equipment Tested/Certified <br /> Check thea roriate boxes to indicates ific equipment ins cted/serviced: <br /> Tank ID: 87 Tank ID: 91 <br /> ®In-Tank Gauging Probe. Model: MAG-1 ®In-Tank Gauging Probe. Model: MAG-1 <br /> ®Annular Space or Vault Sensor. Model: 407 ®Annular Space or Vault Sensor. Model: 407 <br /> ®Piping Sump/Trench Sensor(s). Model: 208 ®Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: LD2000 ®Mechanical Line Leak Detector. Model: LD2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DSL Tank ID: <br /> ®In-Tank Gauging Probe. Model: MAG-1 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 407 ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sensor(s). Model: 208 ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> (9 Mechanical Line Leak Detector. Model: L02000 ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any egni ment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ❑System set-up X Alarm h!iqpry report <br /> Technician Name(print): HEATH MCEVER Signature: <br /> Certification No.: A27562 License.No.. 5236756-UT <br /> Testing Company Name: SST-SERVICE STATION TESTING Phone No.:(209) 465-5577 <br /> Testing Company Address: PO BOX 31465 STOCKTON CA 95213 Date of Testing/Servicing: 1/20/2010 <br /> Page 1 of 3 <br /> Rev(2/08) <br />