Laserfiche WebLink
SWRCB,January 2002 % Page of <br /> 5. SECONDARY PIPE TESTING <br /> Test Method Developed By: ❑Piping Manufacturer ,V Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: Py Pressure ❑Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: NITROGEN Equipment Resolution: PSI <br /> r <br /> Piping Run#91 Piping Run# Piping Run# Piping Run# <br /> Piping Material: FIBERGLASS <br /> Piping Manufacturer: SMITH <br /> Piping Diameter: 3" <br /> Length of Piping Run: 150' <br /> Product Stored: FUEL <br /> Method and location of BOOTED, SUMP <br /> piping-run isolation: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: 1107 <br /> Initial Reading(Rj): 3 psi <br /> Test End Time: 1207 <br /> Final Reading(RF): 3 psi <br /> Test Duration: 1 hr <br /> Change in Reading(RF-Rt): 0 <br /> Pass/Fail Threshold or 0 <br /> Criteria: <br /> Test Result: ,(d Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />