Laserfiche WebLink
SWRCB, January 2002 <br />it <br />Page of <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: ❑ UDC Manufacturer V Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum *44ydrostatic <br />❑ Other (Specie) <br />Test Equipment Used: INCON TS STS <br />Equipment Resolution: .000 1 INCHES <br />UDC # 1-2 <br />UDC # 3-4 <br />UDC # 5-6 <br />UDC # 7-8 <br />UDC Manufacturer: <br />BRAVO <br />BRAVO <br />BRAVO <br />BRAVO <br />UDC Material: <br />STEEL <br />STEEL <br />STEEL <br />STEEL <br />UDC Depth: <br />10 <br />10 <br />10 <br />10 <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />0 <br />0 <br />0 <br />0 <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />0 <br />0 <br />0 <br />0 <br />Condition of UDC prior to <br />testing: <br />GOOD <br />GOOD <br />GOOD <br />GOOD <br />Portion of UDC Tested <br />3" <br />3" <br />3" <br />3" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />❑ Yes ❑ No NA <br />❑ Yes ❑ No A <br />❑ Yes ❑ No RINA <br />❑ Yes ❑ No k'NA <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?* <br />❑ Yes ❑ No X NA <br />❑ Yes ❑ No ANA <br />❑ Yes ❑ No #NA <br />❑ Yes ❑ No WNA <br />fail-safe <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No NA <br />❑ Yes ❑ No XNA <br />❑ Yes ❑ No A <br />❑ Yes ❑ No A <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />Test Start Time: <br />11:02 <br />11:02 <br />12:03 <br />12:03 <br />Initial Reading (Rj): <br />0.3388 <br />0.1434 <br />0.7301 <br />0.2366 <br />Test End Time: <br />11:17 <br />11:17 <br />12:18 <br />12:18 <br />Final Reading (RF): <br />0.3382 <br />0.1433 <br />0.7287 <br />0.2367 <br />Test Duration: <br />15 MIN <br />15 MIN <br />15 min <br />15 min <br />Change in Reading (RF -RI): <br />0.0006 <br />0.0001 <br />0.0014 <br />0.0001 <br />Pass/Fail Threshold or Criteria: <br />.002 <br />.002 <br />.002 <br />.002 <br />Test Result: <br />9 Pass ❑ Fail <br />W Pass ❑ Fail <br />.lam Pass ❑ Fail <br />X Pass ❑ Fail <br />Was sensor removed for testing? <br />Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />Yes []No ❑ NA <br />4 Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />yes []No ❑ NA <br />Yes ❑ No [INA <br />,� Yes El No El NA <br />,� Yes ❑ No [INA <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to qny of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />