My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:39:52 AM
Creation date
6/3/2020 9:54:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
405
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ask <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Dino Mart 1001 E YOSEMITE AVE, MANTECA April 03, 2017 <br /> SUMMARY OF VIOLATION'S <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for TA0508418 (premium unleaded), TA0508419 (diesel), and TA0508420 (regular <br /> unleaded) are not current in CERS. Beneath Tank Construction, under Overfill Protection, change"Yes" to"No"for <br /> Audible/Visual Alarms. Beneath Vent, Vapor Recovery (VR) and Riser/Fill Pipe Piping Construction, complete <br /> sections titled: Vent Primary Containment, Vapor Recovery Primary Containment[not applicable for TA0508419 <br /> (diesel)], Riser Pipe Primary Containment. Beneath Fill Components Installed, change"No" to"Yes"for Striker <br /> Plate/Bottom Portector. Any change of information must be updated in CERS within 30 days of the changes. <br /> Immediately log into CERS, update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For TA0508418 (premium unleaded), <br /> TA0508419 (diesel) and TA0508420 (regular unleaded), beneath Tank Monitoring is Performed Using the Following <br /> Method(s), change "Yes"to"No"for Automatic Tank Gauging. For TA0508418 (premium unleaded) change "Yes" <br /> to"No"for Pipeline Integrity Testing; and beneath Training, change"No"to"Yes" for Designated Operator Training. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. In addition to the submitted map failed to identify the <br /> appropriate monitoring for the dispenser containments (specifically Bravo floats and chains), the submitted map <br /> failed to indicate the locations of the mechanical line leak detectors. A site plan must be submitted identifying the <br /> locations where monitoring will be performed. Immediately log into the California Environmental Reporting System <br /> (CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> On site to complete the annual monitoring system certification testing inspection that initially was begun on <br /> March 9, 2017. This is a billable re-inspection. <br /> Complete and submit a copy of the Return to Compliance Certification form to the Environmental Health <br /> Department (EHD) with a statement documenting the corrective actions that have been or will be taken for each <br /> violation, including violations reported during the March 9, 2017 inspection, and any supporting paperwork, by <br /> May 3, 2017. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> FA0000421 PR0231876 SC333 04/03/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.