My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2023 11:39:52 AM
Creation date
6/3/2020 9:54:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231876_1001 E YOSEMITE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
405
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facilit <br />Name: Valero Quick and Stop Mart Address: 1001 Yosemite Ave., Manteca, CA Daeection Jan 16, 2014 <br />VIOLA RUNS <br /># C1 C2 M Code Section HSC = CA Health and Safe Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />n <br />702 CCR 2643(e) Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M7) <br />703 CCR 2643(d) Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />�R <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />This is a revised report and it supersedes the original report issued at the time of inspection. <br />Onsite to conduct a routine underground storage tank inspection and observe a monitoring system <br />certification conducted today. The monitoring system certification is incomplete since the diesel line leak <br />detector could not be tested due to malfunctioning of the diesel turbine. The monitoring system <br />certification must be conducted in a timely manner. Please be aware that a follow up inspection will be <br />charged at our current hourly rate. <br />Class II Violations: <br />109. Annual monitoring system certification, leak detector testing, and spill container testing was <br />performed on January 15, 2013 and a test report was submitted to the EHD on March 29, 2013. A copy <br />of the test report must be submitted within 30 days of the tests. Ensure that all future reports are <br />submitted to the EHD in a timely manner. <br />112. The diesel UST is not failsafe and does not meet the requirements for annual line tightness testing <br />exemption. Due to malfunctioning of the diesel turbine, the failsafe operation of diesel UST could not be <br />verified at this time. An annual line tightness testing is required unless the UST system is equipped with <br />the following: <br />1. A continuous monitoring system that either activates an audible and visual alarm or stops the flow <br />of product at the dispenser when it detects a leak <br />2. A monitoring system that shuts down the pump or stops the flow of product at the dispenser when <br />it detects a leak <br />3. A monitoring system for piping other than that in UDC sumps (tank top sumps, transition vents, <br />etc.) is failsafe and shuts down pump when a leak is detected <br />Immediately schedule this test and provide 48 hours notification to the EHD. <br />201. No maintenance invoices or repair records were not found on site. These records shall be kept on <br />site for at least 3 years. Immediately locate and maintain these records on site and submit copies to the <br />EHD by February 16, 2014. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Inspector: Received By: Title: <br />Doi Mct.ee w vice rr7as <br />EHD 23-02 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.