My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOCKHEED
>
1941
>
2300 - Underground Storage Tank Program
>
PR0231891
>
COMPLIANCE INFO_2007-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 3:00:31 PM
Creation date
6/3/2020 9:54:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2018
RECORD_ID
PR0231891
PE
2361
FACILITY_ID
FA0003674
FACILITY_NAME
BANK OF STKN AIRPORT HANGAR #3
STREET_NUMBER
1941
Direction
E
STREET_NAME
LOCKHEED
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
1941 E LOCKHEED CT
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231891_1941 E LOCKHEED_2007-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D PROGRAM CONSOLIDATED FOR�M <br /> UNDERGROUNDSTORAGE TANK MW <br /> MONUORING PLAN (Page 2 of 2) <br /> VL UNDER DISPENSER CONTAINMENT((JDC)MONITORING <br /> 1. UDC MONITORING IS PERFORM[ED USING THE FOLLOWING METHOD 490-54a490-54b <br /> 0 1.CONTINUOUS ELECTRONIC MONITORING 0 2.FLOAT AND CHAIN ASSEMBLY 0 3.ELECTRONIC STAND-ALONE <br /> 10 4.NO DISPENSERS 099.OTHER(Specify): 4M56. <br /> PANEL MANUFACTURER: ago-ss MODEL#: <br /> 17 i 1 MODEL#(S): 490-58 <br /> LEAK SENSOR MANUFACTURER: 490- 490-69_ <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS 0 a.YES 0 b.NO <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN El a.YES 0 b.NO 490-60. <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. 0 a.YES 0 b.NO 490-61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER- 0 a.YES F-I b.NO 49042 <br /> 2.UDC CONSTRUCTION IS 0 1.SINGLE-WALLED 0 2.DOUBLE-WALLED 490-63 <br /> IF DOUBLE WALLED: 490-64a <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: [11.LIQUID Q 2.PRESSURE [13.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS Oa.YES Ob.NO 490-64b <br /> VIEL PERIODIC SYSTEM TESTING <br /> D 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 490-65- <br /> LEAK DETECTION(BID <br /> I MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 23 CCR§2644.1) <br /> 2.SECONDARY CONT NT COMPONENTS ARE TESTED EVERY 36 MONTHS. 49066 <br /> 3.SPILL BUCKETS ARE TESTED ANNUALLY. 490-67 <br /> VIIL RECORDKEEPING <br /> The following monitoring/maintenance records are kept for this facility: <br /> *Alarm logs 49o-6sa 0 Visual Inspection Records 4906n 0 Tank integrity testing results 490-6sc <br /> *SIR testing results(and supporting documentation records). 49o-6ad n Tank gauging results(and supporting documentation records). 490ae <br /> *ATG Testing results(and supporting documentation records).49o-68f 0 Corrosion Protection 60-day logs 490-68g <br /> Equipment maintenance and calibration records. 49o-m <br /> DL TRAINING <br /> Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant totheir job duties. 490698 <br /> REFERENCE DOCUTWNTS MAINTAINED AT FACILITY(check all that apply) <br /> 0 THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)490-69b <br /> 0 OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)490-69c <br /> 0 CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-694 <br /> CALIFORNIA UNDERGROUND STORAGE TANK LAW 490-69e <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"49o-69f <br /> 0 SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"49o-69g <br /> 0 OTHER(Specify):M69k M69i <br /> This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> > Operation ofthe UST systems in a manner consistent with the facility's best management practices <br /> > <br /> The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> > The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> > Names of contact person(s)for emergencies and monitoring alarms.49o-7o <br /> X COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan.49o-7i <br /> xiL PERSONNEL RispoNsiirdrifs " <br /> The UST Owner/Operator is responsible for ensuring that:1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The following person(s)are responsible for performing the monitoring and equipment maintenance: <br /> NAME Norman L White 49D-72 TITLE VP Chief Pilot <br /> 490-73 <br /> NAME 4go-74 TITLE 490-75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator,and inform the owner/operator of any <br /> conditions that need follow-up action. - <br /> XM OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the info tion provided in is hue and accurate to the best of my knowledge. 490-77 <br /> APP� IGNATURE 490-76 DATE: <br /> 6a,T., Autbomd <br /> RURES, G_va 1.i8ak E3 1.F.Hil 0 0 gqprq�ye of er <br /> APPLICANT NAME(print): 490-78 APPLICANT TITLE: 9 <br /> A VP Chief Pilot <br /> ME, lia 12, <br />
The URL can be used to link to this page
Your browser does not support the video tag.