Laserfiche WebLink
f <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209) 468-3433 Web:www.smaov.orq/ehd <br /> IJndergrsat d S#orCi Tank Progral tl nspection 13eport <br /> Facility Name: Facility Address: Date: <br /> BANK OF STKN AIRPORT HANGAR#3 1941 E LOCKHEED CT, STOCKTON October 10, 2016 <br /> UST system�bservations <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑V ❑R ❑COS <br /> 324 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> SinglalLe ion <br /> es Pi in <br /> �� ��� � . „ , , 9` <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> or�l� lri1%jolatio�►s '� <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> � <br /> 111MARY Q � ' � - <br /> I'u•t r,' (trL SS ;Gf ASS 11,ofC46 to'Oomplyl <br /> Item# Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The UST Monitoring Plan is not current and not approved by the Environmental Health Department(EHD). In the <br /> UST Tank Information Monitoring Plan, beneath Pipe Monitoring is Performed Using the Following Method(s), <br /> change "Yes"to"No" for Leak Alarm Triggers Automatic Pump Shutdown. This was corrected on site during the <br /> inspection when the designated operator logged into California Environmental Reporting System (CERS), entered <br /> the revision and submitted the revision to CERS. <br /> This is a minor violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to print out the date for the monthly panel tape for the October 22, 2015 designated <br /> operator monthly inspection report; and the designated operator failed to sign the designated operator's monthly <br /> inspection reports for 12/29/15, 3/17/16 and 4/15/16. During the monthly inspection, the designated operator shall <br /> check that all required testing and maintenance for the UST system have been completed and document the dates <br /> they were done. Ensure that designated operators performing monthly inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> FA0003674 PR0231891 SCO01 10/10/2016 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 4 Underground Storage Tank Program OIR J <br />