My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_1998-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 1:45:39 PM
Creation date
6/3/2020 9:54:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2004
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_1998-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY M DATE k/Mbq- <br /> PR# <br /> RVIRONMENTAL HEALTH DEPARTMENT PAGE <br /> 304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility Nam t269 �� (�(L- Facility AddressZ�3 5 7r7A Y & j/f) , <br /> Facilty Contact I,()M RUk( M Title 2 Phone # <br /> UST# Product ' UST#Vmechanical <br /> Product UST# 'I Product 60 UST##Products oll1 <br /> Overfill Prevention: ❑Audible/Vis al Monitoring Panel: (,,y?� <br /> Piping System: ❑Gravity aressure ❑Suction VYes <br /> Violations: J'nor ❑ Major <br /> Automatic Pum Shut Down Satisfies CCR 2636 g : ❑ No Dispenser Pan: G�'es ❑ No <br /> INSPECTION TYPE: ❑Routine ❑Monitoring Certification ❑Complaint ❑Install ❑Removal ❑Repair/Upgrade <br /> COMPANY NAME: TECHNICIAN NAME: PI-104-1,1H.- <br /> VIOLATION(S) <br /> HONE:VIOLATIONS) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): ` <br /> 1 HSC 25284 Permit to operate 20 CCR 2712 (b) Maintenance & monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> month/36 month) 21 CCR 2636 (f)(4) Annual line tightness test <br /> 3 CCR 2711(b)& (c) Current State Forms A& B 22 CCR 2630 (d) Annual line leak detector test <br /> 4 HSC 25292.2 Certification of financial 23 CCR 2630 (d) Annual monitoring certification <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring of suction <br /> / chief financial officer piping that is not continuously <br /> 5 V CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2636 (a) Conventional suction piping <br /> 6 CCR 2636 (c)(1) All releases in secondary piping shall have continuous <br /> flow to a collection sump monitoring & 20 containment <br /> 7HSC 25291 (e) Water in secondary(20)cont 26 CCR 2643 (e) Biennial tightness test of gravit, <br /> HSC 25291 (f) Automatic line leak detector(s) piping that is not continuously . <br /> 9 CCR 2636(f)(1) Continuous monitoring system monitored <br /> for underground piping 27 CCR 2662 Upgrade requirements for UST <br /> 10 CCR 2632 (c)(2) Continuous monitoring system system <br /> for UST 28 CCR 2661 Permit to repair UST system <br /> 11 HSC 25291(a)(2) Secondary containment for 29 HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12_ CCR 2636 (f)(1) Continuous monitoring system 30 HSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system system <br /> 13 CCR 2635(b)(1) Spill container 31 HSC 25298 (b) f Permit to temporarily close US- <br /> 14 CCR 2635(b)(2) Overfill prevention system system <br /> 15 CCR 2631 (a) Primary containment is product- 32 HSC 25298 (c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 20 cont analyzed and <br /> 16 HSC 25292.1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640 (e) Single wall component within <br /> 17 CCR 2650 Recording/reporting 1 000'of Public Well, no ELD <br /> unauthorized release 35 CCR 2635(a)(2)(A)Cathodic protection testing <br /> 18 ( CCR 2632 (d) Monitoring & response plan 36 H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19:LCCR 2712 (i) Monitoring & response plan is 37 Violation(s) not listed above <br /> on site <br /> EHD INSPECTOR: " PHONE:( - q a V <br /> RECEIVED BY: 4 TITLE: <br /> UNITIIWSTANSPOev 724/02) ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.