My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2300 - Underground Storage Tank Program
>
PR0231897
>
COMPLIANCE INFO_2013-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2024 4:22:39 PM
Creation date
6/3/2020 9:54:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2014
RECORD_ID
PR0231897
PE
2361
FACILITY_ID
FA0006443
FACILITY_NAME
Tracy Texaco
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
01
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231897_2375 N TRACY_2013-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
358
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />:Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: TRACY VALERO Bldg. No.: <br />Site Address: <br />Facility Contact <br />Person: <br />2375 TRACY BLVD City: TRACY <br />Zip: <br />HAKAM Contact Phone No.: (209)835-5356 <br />Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 10-11-13 <br />B. Inventory of Equipment Tested/Certified <br />Chock the aooronriate boxes to Indicate specific eauloment inspected/serviced: <br />Tank ID: 87 <br />Tank ID: 88 <br />ID In -Tank Gauging Probe. <br />Model: MAG <br />• In -Tank Gauging Probe. Model: MAG <br />® Annular Space or Vault Sensor. <br />Model: 407 <br />0 Annular Space or Vault Sensor, <br />Model: 407 <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: LD 2000 <br />® Mechanical Line Leak Detector, <br />Model: LD 2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />0 Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: 91 <br />Tank ID: WASTE OIL <br />® In -Tank Gauging Probe. <br />Model: MAG <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: 407 <br />® Annular Space or Vault Sensor, <br />Model: 407 <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: LD 2000 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />DlspenseriD: 3-4 <br />® Dispenser Containment Sensor(s). <br />Model: 332 <br />0 Dispenser Containment Sensor(s). <br />Model: 332 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chatn(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 3-4 <br />Dispenser ID: 5-6 <br />® Dispenser Containment Sensor(s). <br />Model: 332 <br />® Dispenser Containment Sensor(s). <br />Model: 332 <br />® Shear Valve(s). <br />0 Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s), <br />❑ Dispenser Containment Float(s) and Chain(s). <br />`If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified In this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e,g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Piot Pian showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): FELIX RAMIREZ Signature: r, _� <br />Certification No.: 5273934 -UT License No: 08-1740 <br />_..._._. ........... — --........... -- <br />Testing Company Name: AFFORDA-TEST _. Phone No.(209) 7440113 <br />.... <br />— -- - —............ ......_.. . ..... _. <br />Testing Company Address: 41 B 2 _ STREET GALT, CA 05632 _ Date of Testing/Servicing: 10-11-13 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.