Laserfiche WebLink
• i <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared <br />for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br />days of test date. <br />A. General Information <br />Facility Name: Quick Stop Market #144 <br />Site Address: 7272 West Lane <br />Facility Contact Person: Michael Karvelot <br />Make/Model of Monitoring System: Gilbarco EMC <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br />City: Stockton <br />Contact Phone No.: ( 510 <br />Bldg. No.: <br />Zip: 95210 <br />657-8500 <br />Date of Testing/Servicing: 08 /18 /2005 <br />Tank ID: Gasoline -87 <br />Tank ID: Gasoline - 89 <br />■ In -Tank Gauging Probe. <br />Model: 0847390-109 <br />■ In -Tank Gauging Probe. <br />Model: 0847390-109 <br />■ Annular Space or Vault Sensor. <br />Model: 734380-303 <br />■ Annular Space or Vault Sensor. <br />Model: 734380-303 <br />■ Piping Sump / Trench Sensor(s). <br />Model: 734380-208 <br />■ Piping Sump / Trench Sensor(s). <br />Model: 734380-208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />■ Mechanical Line Leak Detector. <br />Model:yapodess 2000 <br />■ Mechanical Line Leak Detector. <br />Model:yaporiess 2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment a and model in Section E on P e 2). <br />❑ Other(specify equipment a and model in Section E on Page 2). <br />Tank ID: Gasoline - 91 <br />Tank ID: <br />■ In -Tank Gauging Probe. <br />Model: 0847390-109 <br />❑ In -Tank Gauging Probe. <br />Model: <br />■ Annular Space or Vault Sensor. <br />Model: 734380-303 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />■ Piping Sump / Trench Sensor(s). <br />Model: 734380-208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />■ Mechanical Line Leak Detector. <br />Model: Red Jacket Fx1 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (speciEy equipment type and model in Section E on Pae 2). <br />Dispenser ID: 1 &2 <br />Dispenser ID: 3&4 <br />■ Dispenser Containment Sensor(s). <br />Model: 734380-208 <br />■ Dispenser Containment Sensor(s). <br />Model: 734380-208 <br />■ Shear Valve(s). <br />■ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑Dis enser Containment Floats and Chain(s). <br />Dispenser ID: 5&6 <br />Dispenser ID: <br />E Dispenser Containment Sensor(s). <br />Model: 734380-208 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />■ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dis enser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Floats and Chain(s). <br />❑ Dispenser Containment Floats and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of g era g such repor�Iha�also <br />attached a copy of the report; (check all that apply): Q System set-up Q histo repo <br />Technician Name (print): Bruce Stewart Signature: — <br />Certification No.: 006-05-0810 <br />License. No.: 617238 <br />Testing Company Name: Walton Engineering, Inc. Phone No.:( 916 )373-1152 <br />Site Address: 3900 Commerce Drive, West Sacramento, CA 95691 Date of Testing/Servicing: 08 / 18 / 2005 <br />UN -036 - 1/4 Page 1 of 3 Rev. 06/04/01 <br />CUPA: San Joaquin County Env. Health <br />INSPECTOR: Dennis Catanyag <br />ALTON <br />`ENGINEERING, INC. <br />www.unidocs.org <br />