My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7272
>
2300 - Underground Storage Tank Program
>
PR0231939
>
COMPLIANCE INFO_2003-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 10:55:58 AM
Creation date
6/3/2020 9:55:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2007
RECORD_ID
PR0231939
PE
2361
FACILITY_ID
FA0002570
FACILITY_NAME
QUIK STOP MARKET #3144
STREET_NUMBER
7272
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
094-040-13
CURRENT_STATUS
01
SITE_LOCATION
7272 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231939_7272 WEST_2003-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPARISER CONTAIN MENT�i1DC) TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Descrintion Dian # 1/2 Dian # 3/4 Dian # 5/6 <br />UDC manufacturer <br />Bravo <br />Bravo <br />Bravo <br />UDC material <br />FRP <br />FRP <br />FRP <br />UDC depth (inches) <br />30" <br />30" <br />30" <br />Height from UDC bottom to highest <br />piping penetration <br />11" <br />3.5913 <br />1.9321 <br />Height from UDC bottom to lowest <br />electrical penetration <br />3" <br />3" <br />3" <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Sensor <br />Sensor <br />Sensor <br />Was sensor removed for testing? <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Yes <br />Yes <br />Depth of water level from UDC bottom (in.) <br />15" <br />15" <br />15" <br />Wait time for water level to stabilize (hr:min) <br />0:10 <br />0:10 <br />0:10 <br />Test start time <br />2:09 PM <br />2:09 PM <br />2:09 PM <br />Initial Probe Reading <br />4.1347 <br />3.5913 <br />1.9321 <br />Test end time <br />2:24 PM <br />2:24 PM <br />2:24 PM <br />Final Probe Reading <br />4.1348 <br />3.5912 <br />1.9319 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (± 0.0000 inches) <br />0.0001 <br />-0.0001 <br />-0.0002 <br />Pass/Fail threshold (±0.0020 inches/ ; Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Comments: <br />© 2004 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.