My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
7272
>
2300 - Underground Storage Tank Program
>
PR0231939
>
COMPLIANCE INFO_2003-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2023 10:55:58 AM
Creation date
6/3/2020 9:55:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2007
RECORD_ID
PR0231939
PE
2361
FACILITY_ID
FA0002570
FACILITY_NAME
QUIK STOP MARKET #3144
STREET_NUMBER
7272
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
094-040-13
CURRENT_STATUS
01
SITE_LOCATION
7272 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231939_7272 WEST_2003-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 .0 <br />D. Results of Testing/Servicing <br />Software Version Installed: 11G.–GO <br />Cmmnlete the following checklist: <br />Yes ❑ No* <br />Is the audible alarm one ational? <br />Yes ❑ No* <br />Is the visual alarm o erational? <br />Yes ❑ No* <br />Were all sensors visual] ictionally tested, and confirmed operational? <br />❑ Yes No* <br />Were all sensors installed at.lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation. <br />® Yes ❑ No <br />If alarms are relayed to a remote monitoring station,. is all communications equipment (e.g. modern) <br />N/A <br />operational? <br />Yes ❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) O(Sump/Trench Sensors; % Dispenser Containment Sensors. <br />Did ou confirm positive shut -down due to leaks and sensor failure/disconnection? Qr Yes, ❑ No. <br />❑ Yes ❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />tj N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill oint(s) and o ratinproperly? If so, at what percent of tank capacity does the alarm trier? <br />If identify specific sensors, probes, or other equipment replaced <br />❑ Yes* No <br />Was any monitoring equipment replaced? yes, <br />and list.the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes* No <br />Was, liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ <br />Product; ❑ Water. If yes, describe causes in Section E, below. <br />Yes ❑ No* <br />Was monitoring system set-up reviewed to ensure proper se.ttin s? Attach set u reports, if applicable <br />Yes ❑ No* <br />Is all monitorin ui mentoperational r manufacturer's specifications? <br />*in Section E below, describe how and when these oen ienci- —j-1 .,, <br />Page 2 of 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.