Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT i!f <br /> UNDERGROUND STORAGE TANK l0 <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(One form per UST) <br /> TYgE OF ACTION (Check one item only. For an UST permanert closure or removal,completeonly this section and Sections I,I1,III,IV,and IX below) alo <br /> R'L NEW PELF IvOR s+1 ❑ 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 4308 I DATE EXISTING UST DISCOVERED: 4306 <br /> L FACILITY,INFORMATION <br /> FACILITY ID#(Agency Use Only) _ _ � r 1 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 <br /> UIK STOP MARKET#144 <br /> BUSINESS SITE ADDRESS 103 1 CITY 104 <br /> 7272 WEST LANE STOCKTON <br /> IL TANK DESCRIP 011 <br /> TANK ID# ;', G(��� 2 TANK MANUFACTURER 437 TAN)c CONFIGURATION: THIS TANK IS 434 <br /> #1 (RUL,87 OCTANE) OWENS-CORNING I.A STAND-ALONE TANK <br /> ❑2.ONE IN A COMPARTMENTED UNIT. <br /> Com fete one page for each com-trnent in the unit. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT -037 <br /> JANUARY 26,1988 10,000 1 <br /> IM TANK USE AND CONTENTS <br /> TANK USE la.MOTOR VEHICLE FUELING ❑ lb.MARINA FUELING ❑ Ic.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 439' <br /> CONTENTS PETROLEUM: Wll..REGULAR UNLEADED ❑ Ic.MIDGRADE UNLEADED ❑ Ib.PREMIUM UNLEADED 440 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 4406 <br /> IV..TANK;:CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL r2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL Wr3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL VNING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL 21.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify) <br /> 4458 <br /> OVERFILL PREVENTION 0 1.AUDIBLE&VISUAL ALARMS U 2.BALL FLOAT 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V.'PRODUCT/WASTE PIPING CONSIMUCTION , <br /> PIPING CONSTRUCTION ❑I.SINGLE-WALLED W2.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE 1.PRESSURE ❑ 2.GRAVITY Ll 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§2636(.x3)] 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL V4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 4646 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPINGfrURBINE CONTAINMENT SUMP TYPE Irl.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 4644 <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER-/F1L ePIPE PIPING CONS TRUtr'[' ON <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL Ork FIBERGLASS Ej 10.RIGID PLASTIC 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 464ei <br /> VENT SECONDARY CONTAINMENT F3 STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC 90.NONE 99.OTHER(Specify) 461`1 <br /> ME <br /> 46411 <br /> VR PRIMARY CONTAINMENT 0 1.STEEL 4.FIBERGLASS 0 10.RIGID PLASTIC 0 90.NONE 0 99.OTHER(Specify) 4648 <br /> 464 l <br /> VR SECONDARY CONTAINMENT 1.STEEL ❑ 4.FIBERGLASS 10.RIGID PLASTIC Ir 90.NONE 0 99.OTHER(Specify) 464h <br /> 464hl <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL 0 2.DOUBLE WALL ir9O.NONE 464i. <br /> RISER PRIMARY CONTAINMENT Irl,STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE Lj 99.OTHER(Specify) 4641 <br /> 464i 1 <br /> RISER SECONDARY CONTAINMENT 1.STEEL ❑ 4.FIBERGLASS 10.RIGID PLASTIC S10.NONE 99.OTHER(Specify) 464k <br /> 464k1 <br /> FILL COMPONENTS INSTALLER Orl.SPILLBUCKET Wr3.STRIKER PLATE/BOTTOM PROTECTOR rfCONTAINIAENTSUMP09 451e-e <br /> VII.UNDERDISPENSER COWONMF1N'T(UDC) <br /> CONSTRUCTION TYPE Wrl.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE "';' 469a <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL Jrk FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469b-c <br /> a . <br /> VIIEt CORROSION PROTBC7'ION <br /> STEEL COMPONENT PROTECTION C12.SACRIFICIAL ANODE(S) [14.IMPRESSED CURRENT 6.ISOLATION 448 <br /> 'IIC.t, PP`LICAIT'SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and in full compliance witjk legal requirements. <br /> APPLICANT SIGNATURE DATE September 1, 2009 azo. <br /> APPLICANT NAME(print) Mike Karvelot, 471. APPLICANT TITLE Director, Environmental Affai 472. <br /> for Quik Stop Markets,Inc. <br /> UPCF UST-B-1/2 Rev.(122007) <br />