My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-1987 PRECISION TESTS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_1985-1987 PRECISION TESTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 11:02:44 AM
Creation date
6/3/2020 9:55:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-1987 PRECISION TESTS
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231945_15999 W CORRAL HOLLOW_1985-1987 PRECISION TESTS.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
301
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> DAMES & MOORE <br /> Tank Testing Service <br /> 221 Main St. , Suite 600 <br /> San Francisco, California 94105 <br /> (415 ) 896-5858 <br /> Tank Owner: Lawrence Livermore Nat' l Lab Test Date: 07/07/87 <br /> Tank Address: P. O. Box 808 L-193 Tank No. : 454 � <br /> Livermore, CA 94550 Product: Diesel <br /> Capacity (gal) : 2000 <br /> Attention: David Castro (415)-423-7556 <br /> Following are the results of precision tests conducted in accordance <br /> with NFPA 329 and State of California criteria on the tank noted above. <br /> [X] System tested tight- [ ] Test indicates a leak. [ ] Test was inconclusive. <br /> -------------------------------------------------------------------------------- <br /> Test period: Lower elevation 0 minutes/Upper elevation 123 minutes. (*) <br /> Test has similar gain/loss at both elevations; indicates a tight system. <br /> Tank test at elevation - inches showed ( ) of __ gal/hour. <br /> Piping/system test at elevation showed ) of gal/hour. <br /> [v-2 Test at elevation .111 showed ( loss) of 0 , 0102 gal/hour. <br /> [IR Test indicates tank is tight. <br /> -------------------------------------------------------------------------------- <br /> Loss/gain attributed to thermal contraction/expansion. <br /> Correction for thermal expansion/contraction was _ gal/hr. <br /> Gain attributed to vapor pocket. [ ] System must be vented and retested. <br /> Retest must be scheduled ( see attached Recommended Procedure) . <br /> -------------------------------------------------------------------------------- <br /> COMMENTS <br /> This system has tested tight. <br /> ryl,17 <br /> Tested by: Maynard Geisler Signature: <br /> Date: 07/12/87 <br /> 0 <br /> Elevations are measured from bottom of tank. <br />
The URL can be used to link to this page
Your browser does not support the video tag.