Laserfiche WebLink
Monitoring System Certification <br />Site Address: Site 300 -Bldg. 879, Corral Hollow Road, Tracy, CA 95376 <br />Date: 9-8-2008 <br />D. Results of Testing/Seiwicing <br />Software Version Installed: 5.03 <br />Camnlete the fallawina rherkli-a- <br />�C <br />0,M-=fft, m=tMW <br />T <br />E. Comments: <br />The Diesel tank is a "Safe Suction" system. <br />Both tanks have mechanical over fill drop tubes. Reports were given to Haz-Mat inspector during the Demo. <br />System has a remote annunciator on outside wall of building, facing tanks. Operation was confirmed during the inspection. <br />UM3= <br />03/01 <br />­Js the audible alarm operational? <br />Is the visual a], <br />Were all sensors visu ffly inspected, ftinctionally tested, and confirmed operational? <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation'? <br />If alarms are relayed to a remote monitoring station. is all communications equipment (e.g. modem) <br />operational? <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a leak. fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all thar applj,) E Sump./Trench Sensors; U Dispenser Containnient Sensors. <br />Did vou confirTtTjsitiv� shut -down due to leaks and sensor failure/disconnection'? K Yes, Q No. <br />tems that utilize the monitoring system as the primary tank overfill warning device (i.e. 110 <br />verfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />nd 2]2�ratin� )roperly? If so, at what percent of tank capacity does the alarm trigger? <br />Mist" WITIUMN1111 <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check- all that app4,) <br />U Product.- U Water. If �es, describe causes in Section E, below. <br />Was monitorin systern set_�P re"Viewed to -ensure proper settings? Attach set���ppi <br />i Is all monitoring equipment 2Erational per niamifacturer's TLcifications? <br />0,M-=fft, m=tMW <br />T <br />E. Comments: <br />The Diesel tank is a "Safe Suction" system. <br />Both tanks have mechanical over fill drop tubes. Reports were given to Haz-Mat inspector during the Demo. <br />System has a remote annunciator on outside wall of building, facing tanks. Operation was confirmed during the inspection. <br />UM3= <br />03/01 <br />